Pump Rsa 95/125; Technical Data; Components; Mounting/Dismounting By-Pass Plug - Bentone B 55-3R Installation And Maintenance Instruction

Table of Contents

Advertisement

7.

Pump RSA 95/125

7.1

Technical data

Viscosity range::
Pressure range at viscosity 1,3-1,8:
Pressure range at viscosity 1,8-18,0:
Oil temperature:
Nozzle capacity at viscosity 4,3:
Gear capacity:
Max pressure on the suction and return side:
7.2

Components

1.
Pressure gauge port G 1/8"
Nozzle outlet G 1/4"
2.
Suction line G 1/4"
3.
4.
Suction line G 1/4"
5.
Return line G 1/4"
6.
Return line G 1/4"
7.
Return plug
Pressure regulation 4 mm Allen key
8.
7.3

Mounting/dismounting by-pass plug

In a 2-pipe-system excess oil is led back direct to the oil tank. In a 1-pipe-
system the by-pass plug must be removed so that there is a free passage back
to the suction side through the return line with the return port closed.(Pos.7).
7.4

Purging

On 1-pipe systems it is necessary to purge the pump. On 2-pipe systems
purging is automatic through the return line.

Replacing the filter

7.5
Replace the oil fiter on the oil pump as follows..
Close the oil valves.
Unscrew the cover (4 x 5 mm Allen screws).
Replace the oil filter.
Replace the cover gasket.
Refit the cover.
Open the oil valves.
RSA 95
RSA 125
1,3-18,0 mm
/s
1,3-18,0 mm
2
5,5-12,0 bar
5,5-12,0 bar
2,5-21,0 bar
2,5-21,0 bar
-10 till+70°C
-10 till+70°C
150-190 l/h
215-260 l/h
225 l/h
294 l/h
4 bar
4 bar
8
6
7
/s
2
1
2
3
4
5
165 105 54
27
Bentone

Advertisement

Table of Contents
loading

Table of Contents