7. Instructions Pump RSA 95/125

7.1

Technical data

Viscosity range::
Pressure range at viscosity 1,3-1,8:
Pressure range at viscosity 1,8-18,0:
Oil temperature:
Nozzle capacity at viscosity 4,3:
Gear capacity:
Max pressure on the suction and return side:

7.2 Components

1.
Pressure gauge port G 1/8"
2.
Nozzle outlet G 1/4"
3.
Suction line G 1/4"
4.
Suction line G 1/4"
5.
Return line G 1/4"
6.
Return line G 1/4"
7.
Return plug
8.
Pressure regulation 4 mm Allen key
7.3 Mounting/dismounting by-pass
plug
In a 2-pipe-system excess oil is led back direct to the oil tank. In a 1-pipe-
system the by-pass plug must be removed so that there is a free passage
back to the suction side through the return line with the return port closed.
(Pos.7).

7.4 Purging

On 1-pipe systems it is necessary to purge the pump. On 2-pipe systems
purging is automatic through the return line.
7.5 Replacing the filter
Replace the oil fiter on the oil pump as follows..
• Close the oil valves.
• Unscrew the cover (4 x 5 mm Allen screws).
• Replace the oil filter.
• Replace the cover gasket.
• Refit the cover.
• Open the oil valves.
28
Bentone
RSA 95
RSA 125
1,3-18,0 mm
2
/s
1,3-18,0 mm
5,5-12,0 bar
5,5-12,0 bar
2,5-21,0 bar
2,5-21,0 bar
-10 till+70°C
-10 till+70°C
150-190 l/h
215-260 l/h
225 l/h
294 l/h
4 bar
4 bar
8
6
7
2
/s
1
2
3
4
5
165 105 54

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bp230uvfr-s3

Table of Contents