Horizontal Terminations - Inline Power Vent -4" X 6-5/8" Rigid Pipe - Regency Fireplace Products City Series Owners & Installation Manual

Direct vent gas power vent fireplace, single sided
Hide thumbs Also See for City Series:
Table of Contents

Advertisement

CV72EPV/CB72EPV/CB40EPV/CC40EPV/CV40EPV/CB60EPV/CV60EPV
Inline Power Vent Vertical or Hortizontal Installation Instructions
Horizontal Terminations - Inline Power Vent
Horizontal Terminations - Inline Power Vent
6-5/8"
Rigid Pipe 4" x
-
Rigid Pipe 4" x 6
5/8" (102 mm - 168 mm)
The minimum components required for a basic horizontal
termination are:
1
Horizontal Termination Cap
1
Power Vent Kit
1
Rigid Pipe Adaptor
1
Length of pipe to suit wall thickness and total vent run
(see Table 1)
Adjustable pipe lengths/slips
Wall thickness is measured from the back standoffs to the inside
mounting surface of termination cap. Create a level surface to mount the
vent terminal. The Terminal must not be recessed into siding. Measure
the wall thickness.
Flat Wall Installation
Wall Thickness
4" - 5-1/2"
(102 mm - 140 mm)
7" - 8-1/2"
(178 mm - 216 mm)
10" - 11-1/2"
(254 mm - 292 mm)
9" - 14-1/2'
(228 mm - 368 mm)
15" - 23-1/2"
(381 mm - 597 mm)
Important:
Maximum total vent length = 72' (21.95 m) with a maximum of six 90
elbows.
One 90
elbow = two 45
elbows.
0
0
Maximum total negative vent length = 7' (2.13 m).
Note: Maximum length of 72' (21.95 m) is based on overall length of
combined chimney components.
Do not run positive venting after a negative run.
Inline power vent location restrictions:
Minimum 4 ft (1.22 m) from the unit
Minimum 1 ft (0.3 m) prior to an elbow.
Minimum 1 ft (0.3 m) following an elbow.
Minimum 1 ft (0.3 m) prior to a termination cap.
Minimum 6 ft (1.8 m) rise from top of unit if there is a negative run.
Power Vent Kit (Part 666-945)
1
770-994
1
911-250/P
1
911-251/P
Amount required for install
1
666-945
1
946-206
1
946-523/P
1
946-763
1
946-506/P
NOTE: Slip section is mandatory.
920-210c
Vent Length Required
6"
(152 mm)
9"
(229 m)
12"
(305 mm)
11" - 14-5/8" Adj. Pipe
(279 mm - 371 mm)
17" - 24" Adj. Pipe
(432 mm - 610 mm)
Table 1
Rigid Pipe Adaptor
45' (13.71 m) -5 Wire BX Cable or
90' (27.43 m) 5-Wire BX Cable
4" x 6-5/8" (102 mm x 168 mm) Rigid Pipe
Power Vent Kit
Vinyl Siding Standoff
Astro Cap Termination
Wall Thimble
Vent Guard
Adj. Pipe Length/Slip
90 Elbow
o
Pipe Length
Vent Reducer
(Part #946-606)
Rigid Pipe Adaptor
CV72EPV shown
0
Sold separately
Sold separately
Sold separately
Sold separately
Sold separately
Sold separately
Sold separately
Sold separately
Sold separately
6
installation
Vent Guard - if required
(Part #946-506/P)
AstroCap
(TM)
Termination Cap
(Part #946-523/P)
Standoff
Wall Thimble
Slip Section
Pipe Length
Power Vent Terminal
CV40EPV City Series |
45
10.04.21