Omron F3SX Series Manual page 3

Safety controllers
Table of Contents

Advertisement

I Safe
The Safety Controller Complies with
Global Safety Standards
In addition to International standards (IEC), the F3SX also conforms to
European (EN), and U.S./Canadian (UL) safety standards, enabling
trouble-free use in machinery for Europe, the U.S., and Canada.
Applicable Standards
• European Machinery Directive 98/37/EC, Low Voltage Directive 73/
23/EEC
• IEC 61508 1998 (EN 61508 2001) (SIL 1-3)
• EN 954-1 1996 (Category B 1-4)
• EN 50178 1997, UL 508, UL 1998, etc.
I Simple
Connection is Easy Using Plug-in Connectors for Even More Readily Accessible
Safety
The wire colors are for reference
purposes only. Refer to individual
international standards for details.
I Visible
Providing Meaningful Safety Equipment Information
that Satisfies Needs for Safety and Peace of Mind
Majority of time lost due to failures is from investigating the causes. In particular,
Previously
most time is spent in determining the location of broken lines or faulty contacts.
Indicator Displays Are Easy to Understand and More Convenient
F3SX
G Normal Operation
Note: Refer to pages H-86 and H-87 for details on indicator patterns.
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA
Tel. 1/888/510-4357
G
No unnecessary wiring between Units allows considerable cuts in the cost of evaluating design safety.
G
Reduced wiring, post terminals, and connector connections enable substantial reductions in the cost of maintenance labor.
G
Width has been reduced by approximately 50% from 225 mm to 112.5 mm max.
products; connecting F3SN (4 sets), F3SP-B1P, and G9SB-301).
G Post terminals aid in
G Convenient F39-TB01 Junction Box for Safety Light Curtain.
preventing uninten-
tional neglect to tight-
en terminal screws.
Main body of machine
Main body of machine
The F3SX uses indicators to show the status of each I/O, contributing
to less time (downtime) spent investigating the cause.
Canada
Tel. 1/866/986-6766
Technology-backed Safety Design
We pursued safety to the limit to deliver safety and reliability
backed by the highest level of safety design and FMEA. Two CPU
Units perform mutual checking and diagnostic monitoring of each
I/O section, and the safety of operations is further
verified by FMEA and process-controlled design
and production.
CPU
(control and monitoring)
Input section
CPU
(control and monitoring)
Control line to monitoring line
FMEA: Failure Mode & Effects Analysis
Using the Connector Cables specially
designed for Safety Light Curtains/Multi-
beam Safety Sensors and a Junction Box for
Safety Light Curtain makes for efficient wiring
to a Control Box installed at a distance.
Direct connection
Direct connection
using F39-JC
using F39-JC@@B
B
Cable with Connectors
Cable with Connectors
on Both Ends
on Both Ends
F39-JC
F39-JC@@T
T
F39-TB01/
F39-TB01
F39-CN5
Safety Relay Unit
G Error
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
Safety Controllers
Damage to power
or circuits
CPU
runaway
Output section
Broken or short-
circuited cable
Damage
to circuit
Output section
Damage
to output
Noise
(compared to previous OMRON
IP65f (oil-resistant)
F39-TB01
Junction Box for
Safety Light Curtain
F39-CN5
T-Connector for
Safety Light Curtains
Control panel
Control panel
F39-JC@@T
Connector Cable for
Safety Light Curtains
Electromagnetic Locking Door Switch
Broken line
F3SX
EE-89

Advertisement

Table of Contents
loading

Table of Contents