F3SX-N-L1D1R Auto-reset Circuit Example
E1
24 V
11
S1
12
A1
T11
T12
T21
Control circuits
24 VDC
E1
24 VDC
A2
SSC
AS3
AS2
E1
24 V
E1
24 V
KM1
KM2
M
S1:
Emergency stop switch with positive opening mechanism A165E or
A22E)
S2:
Reset switch (switch is reset by keeping pressed down for 3 s min.)
S31, S32:
Two-hand control switch
S4, S5:
Safety limit switch with positive opening mechanism (D4D or D4B)
KM1, KM2:
Magnetic contactor
M:
Three-phase motor
E1:
24-VDC power supply (S82K)
External indicator: Filament-type indicator
(When an external indicator is not necessary,
connect resistance of 1/4 W, 4.7 kΩ.)
S6 :
External test switch
AS1:
Auxiliary control output (synchronized with K1, K2 N.O. contacts)
AS2:
Information trigger
AS3:
Standby output
SSC:
Start command input
(Not connected in the above circuit diagram.
When this input is not necessary, connect it to terminal A1.)
Use switches that can be used with microloads (24 VDC, 5 mA).
Note 1.
The above circuit diagram example conforms to Category 2.
Note 2.
In this connection example, the auxiliary output is set
to the standard setting (Dark-ON operation).
To operate using non-standard settings, refer to the catalog or operation manuals
for the F3SN/F3SH.
Note 3.
Two-hand Control Switches are available as 1 N.O. and 1 N.C. types,
conforming to IEC/EN60947-5-1.
Use compliant products.
Make sure the wiring arrangement satisfies EN574.
Use switches that can be used with microloads (24 VDC, 5 mA).
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA
Tel. 1/888/510-4357
S31
S32
S2
24 V
E1
T22
Y1
Y2
Y3
4
8
7
2
6
24 VDC
0 V
AS1
EL1
EL2
FB
15
9
11
16
14
External
indicator
RS-485(A) (gray)
F39-JC@A-L
Connector Cable
(for Emitter)
Emitter
F3SN/F3SH
Canada
Tel. 1/866/986-6766
Stop category
24 V
Safety category EN954-1
E1
11
S4 12
5
3
1
5
6
7
8
Input
Input
circuit
circuit
K1
24 VDC 24 VDC
24 VDC
24 VDC
K2
Input
Input
circuit
circuit
13
12
10
9
10
11
16
S5
12
11
E1
test function of the Light Curtain
24 V
F39-JC@A-D
Connector Cable
(for Receiver)
Timing Chart
Receiver
Emergency stop switch S1
Two-hand control switch
S31 N.C. contact
Two-hand control switch
S31 N.O. contact
Two-hand control switch
S32 N.C. contact
Two-hand control switch
S32 N.O. contact
Reset switch S4
Limit switch S5
Light received
Safety Light Curtain
Light interrupted
K1, K2 N.C. contact
K1, K2 N.O. contact
KM1, KM2 N.C. contact
KM1, KM2 N.O. contact
ON
External indicator
OFF
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
Safety Controllers
IEC60204-1
0
2
Fuses
11
23
33
AC
12
24
34
KM1
KM2
Wiring for use of the
Test
switch
Operates when input time difference is 0.5 s max.
0.5 s max.
F3SX
EE-103