Sweep; Select Sweep; Start Frequency And Stop Frequency; Center Frequency And Frequency Span - Hantek HDG3000C Series User Manual

Arbitrary waveform signal generator
Hide thumbs Also See for HDG3000C Series:
Table of Contents

Advertisement

EN
9

Sweep

In sweep mode, the instrument outputs the waveform that changes from the start
frequency to the stop frequency at a specified sweep rate. HDG3000C supports linear
sweep mode.
Users can configure the instrument to output one sweep from start frequency to stop
frequency by applying an external or manual trigger. The instrument can sweep sine,
square, pulse, ramp, Harmonic or arbitrary waveforms (expect DC).
9.1

Select Sweep

Press [Sweep] button on the front panel to enable the Sweep function (the backlight of
the key goes on), and
enabled).
To avoid multiple waveform changes, enable the sweep mode after configuring the other
parameters (as waveforms and amplitudes of basic waves).
Press [Sweep] button again to close sweep mode.
9.2

Start Frequency and Stop Frequency

The generator sweeps from the start frequency to the stop frequency and then returns
back to the start frequency.
Start Frequency < Stop Frequency: the generator sweeps from low frequency to
high frequency.
Start Frequency > Stop Frequency: the generator sweeps from high frequency to
low frequency.
Start Frequency = Stop Frequency: the generator outputs with a fixed frequency.
When [Sweep] is enabled, press
Freq". The "Stop Freq" in the
numeric keyboard or direction keys and knob to input the desired frequencies. By
default, the start frequency is 100Hz and the stop frequency is 1KHz. Different sweep
waveform corresponds to different start frequency and stop frequency range. For
frequency parameters of different waveforms, please refer to "Frequency
Characteristics" in Specifications.
After modifying the frequency, the generator will restart to output the frequency sweep
signal with the specified frequency.
9.3

Center Frequency and Frequency Span

Users can also set the sweep frequency boundaries of the sweep using a center
frequency and frequency span.
Copyright © Qingdao Hantek Electronics Co., LTD
Mod
or
Burst
function will be automatically disabled (if currently
Start Freq/Center Freq
Stop Freq/Freq Span
softkey to highlight the "Start
softkey is also highlighted. Use the