When any board of this unit is repaired or replaced, adjust this unit for electrical alignment as this section.
Note
• Perform the
"6-4. Video System Level Adjustment"
• Master setup unit MSU-1000/1500 is used for electrical alignment of the unit.
Without using master setup unit (here after MSU), the electrical alignment also can be made using remote control
unit (RCP-1000/1500) or setting menu of the camera.
Refer to
"6-1-7. Setup Menu Correspondence List"
6-1.
Preparations
Turn on the power switch before starting adjustments, and warm up the unit for about 10 minutes.
6-1-1.
Required Equipment, Tool
Note
Use calibrated equipment and tools.
Equipment Required
Name
HD waveform monitor
HD color monitor
Oscilloscope
Frequency counter
Master setup unit
HD viewfinder
Lens
Tool
Name
Grayscale chart (16 : 9 reflective type)
Grayscale chart (16 : 9 transparent type)
Pattern box PTB-500
6-1-2.
File Data at Adjustment
The file structure of the adjustment data of this unit is as follows.
HXC-FB75H/HXC-FB75KC
Section 6
Electrical Alignment
according to the system that the customer uses.
for detail of setup menu.
Equipment
Leader Electronics LV5150DA, Leader Electronics LV5152DA
(multi format) or equivalent
Sony BVM-D20F1A/E/U, BVM-D14H5A/E/U or equivalent
Tektronix TDS460A or equivalent
Advantest TR5821AK or equivalent
Sony MSU-1000/1500
Sony HDVF-20A/200/C30WR/C35W
Canon HJ18 or equivalent
Sony Part No.
Remarks
—
Commercially available
Since time degradation is appeared, replace for every two years.
(The exchange time, change by the safekeeping situation.)
J-6394-080-A
Use when the grayscale chart (16 : 9 reflective type) is not avail-
able.
J-6029-140-B