gateways_10_standby.fm
Standby Board HG 3500
Generation
96
| DC-STATUS = READY
+------------------------------------------------------------------------------+
|
LTU = 3
SLOT = 109
| DC-STATUS = READY
+------------------------------------------------------------------------------+
|
LTU = 17
SLOT = 2
| DC-STATUS = READY
+------------------------------------------------------------------------------+
If board 1-3-49 now becomes defective, all board data and all IP stations are
switched to standby board 1-3-109. This provides the following AMO BPOOL
output after the switchover:
DIS-BPOOL;
H500: AMO BPOOL STARTED
+------------------------------------------------------------------------------+
| POOLNO = 1
| INFO = TEST1
+------------------------------------------------------------------------------+
| LTU = 3
SLOT = 49
| DC-STATUS = NPR
| SWITCHED AUTTO BRD LTU = 3
+------------------------------------------------------------------------------+
| LTU = 3
SLOT = 109
| DC-STATUS = READY
| SWITCHED AUTFR BRD LTU = 3
+------------------------------------------------------------------------------+
| LTU = 17
SLOT = 2
| DC-STATUS = READY
+------------------------------------------------------------------------------+
Explanation of important abbreviations in the output:
HOPAUT: Automatic switchover between the boards in this pool is permitted
once (SINGLE) or several times (MULTI).
SMODE: Standby mode (see
HOP-AUT-CNT: Number of automatic switchovers
HOP-MAN-CNT: Number of manual switchovers
DC-STATUS: The board's DC status (see also AMO SDSU)
LAN_VERB: LAN connection status; READY generally means "LAN cable
connected", DEF means "LAN cable disconnected or defective". If the field is
empty, the LAN connection has a DC status which does not get interpreted by
the AMO BPOOL. In this case, the LAN status has no effect on switchover. If
this is of interest, you can use the AMO SDSU.
The following history data is only displayed after a switchover:
SWITCHED AUTFR BRD: The IP stations were automatically switched away
from this board (for example, on account of a defect) (see also DATE/TIME)
SWITCHED AUTTO BRD: The IP stations were automatically switched back
to this board (for example, on account of a defect in another board) (see also
DATE/TIME)
HiPath 4000 V5, IP Solutions - HG 3500 & HG 3575, Service Documentation
LAN_VERB = READY
HOP-AUT-CNT = 0
LAN_VERB = READY
HOP-AUT-CNT = 0
LAN_VERB = READY
MTYPE = CGW
HOP-AUT-CNT = 0
LAN_VERB =
SLOT = 109
DATE/TIME : 2003-09-25 18:07 |
HOP-AUT-CNT = 1
LAN_VERB = READY
SLOT = 49
DATE/TIME : 2003-09-25 18:07 |
HOP-AUT-CNT = 0
LAN_VERB = READY
Section 10.3, "Service
A31003-H3150-S104-2-7620, 03/2009
SMODE = NORMAL
|
HOP-MAN-CNT = 0
|
SMODE = STBYRDY
|
HOP-MAN-CNT = 0
|
SMODE = NORMAL
|
HOPAUT = SINGLE |
|
HOP-MAN-CNT = 0
|
SMODE = STBYDEF
|
HOP-MAN-CNT = 0
|
SMODE = NORMAL
|
HOP-MAN-CNT = 0
|
SMODE = NORMAL
|
Information")