It is not necessary to delete all circuits on the module and the module itself,
but rather to change the part number with CHANGE-BCSU (if necessary).
CHANGE-
BCSU:TYPE=PARTNO,LTG=<ltg>,LTU=<ltu>,SLOT=<slot>,PARTNO1=<par
t number of board to be changed>,PARTNO2=<part number of new
board>;
Restart the board with
RESTART-BSSU:ADDRTYPE=PEN,LTG=<ltg>,LTU=<ltu>,SLOT=<slot>;

4.1.5 Feature Capacities

Information on feature capacities for both HG 3500 V4 and HG 3575 V4 see
Chapter 5, "Features and
The HiPath HG 3500 V4 gateway has the capacity to convert 60/120
connections into Fast Ethernet packets and provide TDM to IP conversion for
60/120 concurrent calls.
HG 3500 V4 gateways can be configured as a standby gateways providing
backup capabilities in case of individual gateway failure.
More detailed information on standby gateways
One or multiple standby HG 3500 IP line gateways can be defined in the
system that will take over in case any of the installed line gateways fails.
This concept is very efficient and cost effective because a single gateway can
protect multiple gateways against failure. However, a single gateway cannot
protect against multiple gateways failing simultaneously, which is highly
unlikely.
In case of a failure, the system will reprogram a standby gateway with the
parameters of the failed gateway which will enable the IP clients to re-login
and resume standard operation.
IP phones will automatically register with the activated standby gateway and
no administrative action is required. Note that users keep the same features
and extensions while operating off the standby gateway.
HG 3500 V4 (Common Gateway)
Restrictions".