Installation and Operating Instructions for Brake EV/EH 018/024/028/038 FEM-240M/480M E 09.769e Schaberweg 30-38 Phone +49 6172 275 0 www.ringspann.com 61348 Bad Homburg +49 6172 275 275 info@ringspann.com Germany...
Page 2
Disregarding or misinterpreting these installation and operating instructions invalidates any product liability or guarantee by RINGSPANN; the same applies if the product is taken apart or changed. These installation and operating instructions should be kept in a safe place and should accompany the product if it is passed on to others -either on its own or as part of a machine- to make it accessible to the user.
5. Condition upon Delivery 6. Handling and Storage 7. Technical Requirements for Safe and Reliable Operation 8. Installation of the RINGSPANN Brake 8.1 General Instruction for Assembly and Installation 8.2 Prior Assembly and Installation 8.3 Adjust to the Brake Disc Thickness and Mounting the Brake 8.4 Electrical Connection...
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 4 General remarks General safety instructions Please read these installation and operating instructions carefully before installing and operating the brake.
No adjustments necessary, the brake can only be used with 50Hz or 60Hz. UL508 or CSA c22.2 No14-13 cover only ambient temperatures between 0° and +40°C. Technically lower or higher temperatures are possible, consultation with Ringspann is necessary. Measured according IEC 61672-2 “Fast” , with max. clamping force.
The brake is designed for use as a holding/parking brake and/or stopping brake. Other uses are improper and incompatible with the specified purpose. RINGSPANN assumes no liability for damages resulting from improper use. The risk is assumed by the user alone.
"Bourns 1250-xS-230" can be used. In 480V mains surge protectors type "Bourns 1250-2S-400" can be used. Installation of the RINGSPANN brake 8.1 General instructions for assembly and installation Before installing the brake, the brake disc must be cleaned with alcohol, e.g. ethyl or isopropyl alcohol or a water-based surfactant solution (soapy water, etc.) and then rubbed dry with a clean...
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 8 Please note! Oil and rust-proofing-agent residues reduced friction coefficient and thus dimin- ish transmissible braking torque substantially! 8.2 Prior assembly and installation Prior to installation, check to ensure that the mounting surface is even and planned run between the brake disc and the mounting surface is within the tolerance range of 0.2 mm.
Page 9
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 9 Type EH 018.. EH 024.. EH 028.. EH 038.. Distance X 60,5 mm 84,5 mm 99 mm 126 mm...
Before replacing the electronic, check the coil of the solenoid to be shure that the coil is not damaged. Please consult RINGSPANN. • Cable bushing or plug is in the scope of delivery. • The brake can only be used with 50Hz or 60Hz, single phase, no adjustment is necessary.
Page 11
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 11 Brake size 018 For the size 018 the electronic is not attached to the brake, the seperate electronic module is to be used.
Page 12
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 12 Brake size 024, 028 and 038: Supply voltage (mains), sin- gle phase (L and N can be swapped) Fig.
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 13 The braking force is adjusted to the maximum braking force. If the braking force should be re- duced, the clamping force can be reduced by reducing the pretension of the spring.
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 14 9. Commissioning Attention! To switch the brake without brake disc is only allowed if the assembly locking nut Pos.
Brake pads must not be worn to a residual thickness (mounting plate thickness plus remaining pad material). Brake pads must always be replaced in pairs. Only original RINGSPANN brake pads may be used. Brake pad wear adjustment: To counter brake pad wear you can adjust the distance between brake pad and brake disc with set screws Pos.
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 16 Brake pad replacement: Before replacing the brake pads Pos. 1, ensure that the mass held by the brake is secured to prevent movement, as parts of the brake must be loosened/removed for replacement.
Page 17
NC or NO version (see figure 12.2; 12.3 and 12.4). For sensor kits with more than one sensor or for special requirements, such as other voltage ranges or low temperatures below - 25°C, please contact RINGSPANN. Sensor kit:...
Page 18
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 18 Brake status indication size 018 and 024: Brake open (NC) Brake pad wear adjustment necessary (NO) Brake closed (NO) Fig.
Page 19
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 19 For inductive proximity switch 3504-000071-000000: Switching function : NPN (Opener, NC) Sensing range : 4 mm, flush Operating voltage : 10..30 V DC...
For the purpose of EC-Low voltage directive 2014/35/EU We hereby declare that the following products, developed, designed and manufactured by our own responsibility, are In accordance with the EC-Low voltage directive 2014/35 / EU RINGSPANN GmbH Schaberweg 30-38 D-61348 Bad Homburg...
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 22 15. Drawing and Parts list Information! For a clear assignment the 16 digit part number of the brake is necessary. Quantity Part Nomenclature...
Page 23
Installation and Operating Instructions for Brake E 09.769e EV/EH 018/024/028/038 FEM, Spring activated – electromagnetically released issue: 04.01.2023 version: 3 drawn.:BAHS checked.: EISF pages: 21 page: 23 Threaded pin with hexagon head Threaded pin Slide bushing Wiper Washer DIN125 Hexagon nut DIN985 Hexagon socket head cap screw DIN912 Washer DIN125 Hexagon nut DIN934...
Need help?
Do you have a question about the EV 018 FEM-240M and is the answer not in the manual?
Questions and answers