6 Maintenance
6.8.2.2 Remove the locking assembly
1. Locking assembly
2. Plug × 4
3. Screw × 12
4. Propeller hub
5. Shaft
1. Remove the screws.
The locking assembly should become released.
2. If the assembly stays locked after loosening the screws, then do the following:
a) Remove the four plugs.
b) Install four of the screws that were removed.
c) Tighten the screws evenly until the locking assembly is released.
d) Remove the screws.
6.8.2.3 Remove the propeller hub
Table 15: Tools
Tool
Hydraulic pump
14-57 21 04
58
1
Illustration
1. Threaded adapter
2. Non-threaded adapter
2
3
4
1
P7900 Installation, Operation, and Maintenance Manual