Xylem FLYFT P7900 Installation, Operation And Maintenance Manual page 31

Table of Contents

Advertisement

a) Check that the communication between the pump and the MAS base unit is activated.
b) Upload the factory settings of sensors and related parameters by choosing the
4. Connect the power cable:
a) Check the data plate to determine which connection is valid for the voltage supply.
b) Arrange the connection on the terminal board.
c) Connect the power cable leads to the terminal board connection U1, U2, V1, V2, W1,
d) If control elements are present and not used, then cut and cap them.
5. Install the entrance flange:
a) Fit the entrance flange parts according to the illustration for the correct drive unit.
P7900 Installation, Operation, and Maintenance Manual
command "copy all from pump memory to MAS". For more information about the MAS
installation, see the Installation and User Manual for the MAS 711 monitoring
equipment.
W2, and ground (earth) according to the cable chart.
See
Cable charts
on page 36.
2
1
5
1. Seal sleeve
2. Spacer ring
3. Seal sleeve
4. O-ring
5. Washer
Figure 10: Drive units 705–776
10
8
9
11
1. Protective sleeve
2. Washer
3. Connection flange
4. Washer
5. Seal sleeve
6. Washer
7. O-ring
8. Spacer ring
9. Washer
10. Seal sleeve
11. Washer
Figure 11: Drive unit
Pumps with drive units 705–776 are also equipped with a cable holder illustrated
here.
3
4
6
4
7
5
2
3
4 Installation
1
29