Advertisement
(Front Body, installation on the outside of the door)
Optional Accessories
Parts | Specifications | Remarks |
Front Body | 68(W) X 335(H) X 26.5(D) mm | Operating temperature -15~55˚C (5~131 ˚F) |
Main Body | 72(W) X 344(H) X 36(D) mm | |
Battery | 4EA 1.5V AA Alkaline batteries(Operating voltage: 4.5~6V) | |
Optional product | Remote controller, Module and etc |
※ Battery life may vary depending on temperature, moisture levels, frequency of use and the quality of the batteries.
(Main Body, installation on the inside of the door)
Normal Mode: Without a designated person, anyone who knows 'User PIN Code' has authority to set features.
Master Code: Only a designated person who knows 'Master PIN Code' has authority to set features.
Visitor Code: The visitor code is different from user code and given out to visitors only.
Onetime Code: The onetime code is used only once for unlocking the door lock and automatically deleted after usage.
User Slot Number: It should be 2 digits(like '01', '02'...'99', '00') and available in advanced mode.
Touch the Keypad of the Front Body with your palm to begin | |
Press button on the Keypad | |
Press button on the Keypad | |
Press (Registration) button in every steps to start or complete the session | |
Enter User Card Key (Up to 100EA) | |
Enter User Fingerprint (Up to 100EA) | |
Enter User Code (4 ~ 10 digits) | |
Enter Master Code (4 ~ 10 digits) | |
Enter Visitor Code (Only 4 digits) | |
Enter Onetime Code (Only 4 digits) | |
User Slot Number should be 2 digits (like '01'... '99' and '00': Location of 100th user slot must be assigned "00" instead of "100". ) | |
Rotation area to add more features |
One-touch Fingerprint Verification
Easy Scan by Goodix fingerprint solution: Live finger detection and secure matching The leading liveness performance improves the security of Yale smart lock dramatically.
Yale Access Bluetooth App (Yale Access BLE module: optional item)
This service is an innovative solution provided by YALE. Using high-tech IoT technology, user can access and unlock the digital door lock with your smartphone.
Smart Touchpad Automatic Locking
The automatic lock sensor detects the door closing and locks the door automatically within 5 seconds. The door locks when touch the keypad with the palm.
As the automatic lock function does not work in manual lock mode, make sure to check that the door is securely locked when leaving the premises.
3 minute Lock Out Feature
After five (5) unsuccessful attempts of an invalid code or fingerprint, card key lock out mode is activated for 3 minutes.
Smart Etiquette
When entering a pin code on the keypad, the user can open the door lock in silent mode.
Fake PIN Code
Security enhancement to enter any number before or after entering a password to prevent the PIN code from being exposed.
Internal Forced Lock
It is a security-enhancing function that 'disables' authentication methods such as passwords, RFID cards and fingerprints from outside when setting up functions indoors.
External Forced Lock
It is a security-enhancing function that an alarm goes off if someone opens door from inside when setting up functions outside.
Voice Guide Feature
It guides user the operation status how to set each features, mode for easier and more convenient use.
Other features and Benefits
Normal mode is a convenient mode for anyone to set the digital door lock. User can set password like user code, visitor code, onetime code and register user's fingerprints, card keys as well. Factory default is a normal mode.
Only 1EA
How to press set button of remote controller
Press the set(registration) button located on the front of remote controller. You can press it using a pin like the picture.
Please note the following when using Yale Access Bluetooth App.
Contact registered Card Key
To disable Safe Handle Setting
To enable Safe Handle Setting
From Outside
Press the lever handle down to open door
From Inside
To open when Safe Handle Settings are enabled:
Keep pushing the safe handle button. And then, Press the handle down to open the door.
To open when Safe Handle Settings are disabled:
Press the lever handle down and open the door.
Internal Forced Lock
Close the door and then move the lock button to "LOCK" position.
Automatic Lock Mode(Inside/Outside)
In automatic lock mode, the lock automatically locked within 5 seconds after closing the door and detecting the automatic lock sensor.
Manual Lock Mode
The door locks when touching the keypad with the palm. (outside)
Use Thumb turn knob on the main body. (Inside)
Automatic Lock Setting
Release the button to set automatic lock mode on the main-body (after opening the battery cover)
Manual Lock Setting
Press the button to set manual lock mode on the main-body.
External Forced Lock Setting-Fingerprint
Scan with registered Fingerprint and hold the fingerprint area until you hear 3 beep sounds.
External Forced Lock Setting – User Code
External Forced Lock Setting – Card Key
Contact Card Key on [Card Key reader] for 5 sec. until you hear 3 beeps.
Releasing External Forced Lock Setting
When the door is unlocked from outside based upon proper authentication, the External forced lock will be released.
The operation sound volume will be adjusted according to the Volume Switch setting.
If an invalid user code, fingerprint or card key is entered five(5) times in a row, lock out mode is activated and all buttons on the front body are not activated for three minutes.
To Release 3-minute Lock Out
Intrusion Alarm: The alarm goes off when someone forces the door open. For example, In case of an intrusion by opening a gap in the door while the door is locked.
Broken Alarm: The alarm sounds when the front part is completely separated from the main set. For example, forced removal of external product (front body).
To turn off alarm
※ In case of discharged batteries, please use 9V battery to supply power
The product uses four 1.5V Alkaline AA batteries. They may sustain 1 year if used 10 times a day. (Users are advised to use authentic Alkaline batteries.)
You must replace all 4 batteries in the following cases:
* The Low Battery LED on keypad flickers red.
* When low battery notification message is played.
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE NATIONAL CODE OR RECYCLING PROGRAM.
Duplicate if necessary
PIN Code Management(Up to 100 Users.) | ||
Master mode is a mode in which only the administrator can set the door lock and provide access to other users. 100ea user passwords, 100ea card keys, 100ea fingerprint and individual registration and deletion of one-time passwords enable efficient management of visitors.
User Slot Number should be 2 digits.
like '01'... '99' and '00': Location of 100th user slot must be assigned "00" instead of "100".
※ Voice guidance function: The lock provides voice guidance for user and it will be helpful to set up lock's features correctly.
※ All registered passwords and other credentials can be deleted at the time of mode change.
※ Please install(register) the network module when you want to use a remote control or home network.
Do not install the digital door lock in an outdoor environment.
Do not spray water directly or wipe with chemicals such as benzene, gasoline or alcohol.
When using, remember that someone else can see the password.
Do not attempt to disassemble the digital door lock by yourself.
Do not use force with a tool onto the product.
Make sure to lock the door tight when you go out.
PLEASE READ INSTRUCTIONS BEFORE USE.
The functions and design of this product can be changed without prior notice for performance and quality improvement.
Packaging of this product can be recycled.
WEEE Note: Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check your local authority or retailer for recycling advice.