5. INSTALLATION

5.1 Built-in installation
single appliance
For a built-in installation, to close gaps between
the appliance and the adjacent cabinets, special
side profiles and PVC covering frames are provi-
ded.
Operate as follows:
>
Push the appliance into the installation niche
1
>
If the unit is to be installed inside a niche or
within an enclosed structure, it is necessary to
design a ventilation shaft at the back of the ni-
che to assure proper ventilation at the back of the
unit. A 5 mm gap is sufficient to prevent overhe-
ating. Always mount front panels on door and
drawer before pushing the unit into its final posi-
tion inside the niche or structure.
>
Secure the appliance to the adjacent cabinets
by fixing to these the side profiles previously
mounted on the appliance
To make this operation easier keep the door and
the drawer open.
>
Check the levelling of the appliance, adjusting
its feet and wheels to correct it.
2
>
Mount the profiles the covering frames: first in-
sert them laterally and then push firmly until a
"click" is heard
[ 3
].
[ 1
].
[ 2
].
3
Side profiles mounting:
Appliance
Wall or furniture
22 ( ⁄ ")
A PVC connecting element,
alternatively: C plastic connecting brackets
B Alluminium frame
5.2 Built-in installation two or more
appliances
Required accessories to be ordered separately:
>
Central connection Kit (KCC)
Special side profiles and PVC covering fra-
mes are provided for closing gaps between
the appliance and the adjacent cabinets.
Operate as follows:
>
Position the appliances in front of the installation
area, leaving enugh space to operate at their back
[ 1
].
1
C
A
B
22 ( ⁄ ")
21