The integration function is described by:
Notice that any signal under the input zero scale (low limit of the range or
Eng Low) is not integrated, that is, the totalization does not decrease.
When exceeding the maximum limite of counts (9999), the most significant
digits which would appear in the totalization are ignored, but it is keept the last
increment calculated, in order not to loose precision in the counts after passing by
succesive "overflows".
The totalization count of a channel may be reset by the RSET option in the
Totalization Level, or by pressing the ACK key when the totalization is shown in the
operation level. Note that the use of the ACK key for reset must be enabled by the
OPER option.
Level 5 - Calibration
Level 5 is described on section 4.4 on Calibration.
Level 6 - RS
Refer to the communication manual.