Configuration

4.9 Configuring the properties of the TF-CPU

Step
Description
6
Follow the instructions in the online help if necessary.
Confirm the entries with OK.
Result
The configured safety-related communication link between Integrated Technology (I-slave) and the drive
(PROFIsafe module) is now displayed.
7
Click OK to close all dialogs.
4.9
Configuring the properties of the TF-CPU
Procedure
Step
Activity
1
Open the properties of the CPU 317TF-2 DP in HW Config.
2
Make the following settings in the "Protection level" section of the "Protection" tab:
Select the "Can be bypassed with password" option under "1: Access protection for F-CPU".
In the "Password" box, enter a password for the F-CPU (max. 8 characters) and repeat your entry in the "Enter
again" box.
Select the "CPU contains safety program" option.
3
Confirm the entries with OK.
4
Save and compile the hardware configuration.
5
Download the hardware configuration to the CPU using the menu command PLC > Download to Module.
46
CPU 317TF-2 DP: Controlling a SINAMICS S120 with Safety Functions