Location

When locating this unit, convenience and accessibility are important considerations, but the following factors must be
observed:
1. Proximity to a 3-prong 115VAC receptacle for grounding
2. No clearance is required on the sides or back of the unit. The unit must be operated with the legs in place and
the top of the unit must be clear of obstruction.
The unit may be located in the drive-through area, on the front counter or in the drink area, whichever is more
convenient.

Electrical Connections

Prior to connecting the unit to power, be sure to check the data plate, located on the inside of the cabinet, for
required voltage. The specifications on the data plate supersede any information contained in this manual.
The standard unit is equipped with a seven (6) foot (2) inch power cord extending from the bottom of the unit. The unit
requires a 115 Volt, 60 Cycle, 1 Phase properly grounded electrical receptacle protected with a 15 or 20 ampere fuse or
breaker. The power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding spike
or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturer's responsibility and could
result in serious injury.

Safety

FOR HYDROCARBON UNITS ONLY (R290)
Danger – Risk of fire or explosion. Flammable refrigerant used. To be repaired only by trained service personnel.
Do not puncture refrigeration tubing.
Danger – Risk of fire or explosion. Flammable refrigerant used. Do not use mechanical devices to defrost
refrigerator/freezer. Do not puncture refrigeration tubing.
Caution – Risk of fire or explosion. Flammable refrigerant used. Consult repair manual/owner's guide before
attempting to service this product. All safety precautions must be followed.
Caution – Risk of fire or explosion. To be repaired only by trained service personnel. Use only Silver King approved
replacement parts. Flammable refrigerant used.
Caution – Risk of fire or explosion. Dispose of properly in accordance with federal or local regulations. Flammable
refrigerant used.
CAUTION: Risk of Electric Shock
Always unplug the power cord before servicing the unit to avoid electric shock.
Unit MUST be plugged into a 3 prong plug for grounding. Cutting off the grounding spike on the power cord could
result in electric shock to the operator during operation.
Unit must be plugged into a 15 or 20 ampere fuse or breaker protected circuit. Use of a larger fuse or breaker
could result in damage to the unit and electric shock to the operator.
Moving and/or Hot Parts
• Some parts may remain hot even after being unplugged. Always use caution when servicing.
Possible Back Injury
• Assistance should be utilized when moving this piece of equipment.
• Be sure to lift with your legs and not your back when lifting this unit.