Silver King SKPZ92-EDUS2 Technical Manual And Replacement Parts List

Prep tables

Advertisement

Quick Links

Technical Manual
and
Replacement Parts List
Prep Tables
MODEL: SKPZ92-EDUS2
Marmon Foodservice Technologies
355 Kehoe Blvd., Carol Stream, IL 60188
Contact: (800) 328-3329
Silverking.com
FORM NO. 46705 REV A 04/2020
Specifications Subject to Change Without Notice.
1

Advertisement

Table of Contents
loading

Summary of Contents for Silver King SKPZ92-EDUS2

  • Page 1 Technical Manual Replacement Parts List Prep Tables MODEL: SKPZ92-EDUS2 Marmon Foodservice Technologies 355 Kehoe Blvd., Carol Stream, IL 60188 Contact: (800) 328-3329 Silverking.com FORM NO. 46705 REV A 04/2020 Specifications Subject to Change Without Notice.
  • Page 2 INSPECT FOR DAMAGE AND UNCRATE Upon delivery of your new Silver King unit, uncrate at once to inspect for possible freight damage following the instructions printed on the exterior of the container. Report any damages to the carrier responsible for transportation and promptly present a claim for any evidence of mishandling.
  • Page 3: Different Types Of Alerts

    Risk of fire or explosion. Flammable refrigerant used. Consult repair manual/owner’s guide before attempting to service this product. All safety precautions must be followed. Caution – Risk of fire or explosion. To be repaired only by trained service personnel. Use only Silver King approved replacement parts. Flammable refrigerant used. Caution –...
  • Page 4 SAFETY PRECAUTIONS (Continued): WARNING - Do not use electrical appliances inside the food/ice storage compartments unless they are of the type recommended by the manufacturer. WARNING - Appliances and their surroundings shall not attain excessive temperatures in normal use. WARNING - Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • Page 5: Installation

    The unit can be installed tight on the sides. • The unit must be level or tilted backwards slightly. Climate Class Rating Your Silver King Prep Table has a climate class 4 rating. It is designed for use in areas not exceeding 30°C (86°F).
  • Page 6 R290 R PECIALIZED RECAUTIONS AND UIDELINES FOR ERVICING NITS SING EFRIGERANT: Qualification of Service Personnel/Workers: Required qualification of working personnel for maintenance, service and repair operations. Every working procedure that affects safety means shall only be carried out by competent persons. Examples for such working procedures are: ·...
  • Page 7 Checks to the Refrigeration Equipment: Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.
  • Page 8 Cabling: Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse physical or environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
  • Page 9: Charging Procedures

    Charging Procedures: In addition to conventional charging procedures, the following requirements shall be followed. WARNING: Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them. WARNING: Cylinders shall be kept in an appropriate position according to the instructions.
  • Page 10: Operation

    Defrost Your Silver King refrigerator is an automatic defrost unit and no additional plumbing is required. Automatic defrosting is accomplished when frost buildup on the Evaporator Coil is cleared during Compressor off cycles. Defrost water is collected in a pan located in the compressor compartment where it is evaporated into the room air.
  • Page 13 LIST REPLACEMENT PARTS – SKPZ92-EDUS2 ITEM NO DESCRIPTION PART NUMBER BRACKET AIR DIVIDER 38221 BACK PANEL LH 46708 BACK PANEL RH 46709 DRIER 22677 TEMPERATURE CONTROL 115V (PROGRAMMED) 46723 COMPRESSOR KIT 115V (W/ DRIER & ELECTRICALS) 11700-11 KIT ELECTRICALS FOR COMPRESSOR 115V...
  • Page 15 Thermistor Field Testing Use the guide below to test if a thermistor (temperature probe) is functioning properly. See the replacement parts list for part number information. Table 2 is valid for all thermistors listed on table 1. • Establish Thermistor Temperature Table 2 ▪...
  • Page 16 90 DAY REPLACEMENT PARTS WARRANTY Silver King warrants to the original Equipment purchaser that a replacement OEM part thereof will be free of defects in material and workmanship, under normal use and service, for a period of 90 days from the date of original purchase of such replacement OEM part subject to all terms and conditions herein.
  • Page 17 Silver King’s review to be inefficient or inoperative due to defects in material or factory workmanship.
  • Page 18: Product Ordering Information

    An RMA (Returned Merchandise Authorization) form must be completed and then approved by Silver King. Please contact Silver King for details. Restocking fee will apply. All electrical equipment is single phase. Prices, designs, and specifications are subject to change without notice.

Table of Contents