Graco PM8 Repair Instructions page 22

Hide thumbs Also See for PM8:
Table of Contents

Advertisement

Repair
27
F
. 50
IG
14. Assemble the valve housing (27) and the meter
housing (10) while gently pulling the solenoid wires
(14a) through the access hole on the meter housing
(10) (F
. 51).
IG
27
F
. 51
IG
22
13
14a
10
15. Replace the two cap screws (22) and torque to 60
to 72 in-lbs (6.78 to 8.13 N•m), see F
19.
16. Reconnect the solenoid wires (14a) to the terminal
block on the bezel (1). The wires are polarity
independent so place one wire in each terminal
opening, see F
. 40 on page 19.
IG
Optional - replace batteries (36) with four (4) new
alkaline batteries.
17. Route the solenoid and the battery wires as shown
in F
. 5 on page 9.
IG
18. Position the bezel (1) so the display is in the upright
position when holding the valve.
19. Reassemble the bezel (1) to the meter housing (10),
see F
. 39 on page 19.
IG
20. Replace the four screws (9) and torque to 15 to 25
in-lbs (1.69 to 2.82 N•m), see F
21. Reassemble the impact guard (37), see F
page 18.
22. Replace the meter onto the hose.
. 41 on page
IG
. 38 on page 18.
IG
. 37 on
IG
3A8560C