9. Remove the cap screws (22) (F
22
F
. 10
IG
10. Pull the valve housing (27) apart from the meter
housing (10) while simultaneously feeding the
solenoid wires (14a) into the meter housing (10)
access hole (F
. 11).
IG
27
Access
Hole
F
. 11
IG
11. Remove and discard the smaller gasket (2) located
between the meter housing (10) and the valve
housing (27), see F
IG
12. Replace the smaller gasket (2) with the new one
from the kit, adhesive side on the meter housing
(10), see F
. 8 on page 10.
IG
3A8560C
. 10).
IG
14a
10
. 8 on page 10.
Reassembly
1. Lubricate the connection tube o-rings (12) with oil
(F
. 12).
IG
NOTE: It is not required that the connection tube (13) be
disassembled from both the valve housing (27) and the
meter housing (10). If the connection tube (13) is still
assembled to either component, lubricate the visible
o-ring and proceed to Step 3.
F
. 12
IG
2. Install the connection tube (13) into the valve
housing (27), long end first. The connection tube
(13) needs to be correctly oriented or the meter and
the valve housings will be unable to be fully
assembled (F
. 13).
IG
F
. 13
IG
3. Assemble the valve housing (27) and the meter
housing (10) while gently pulling the solenoid wires
(14a) through the access hole on the meter housing
(10) (F
. 14).
IG