Repair
5. Squeeze the trigger, then latch the trigger latch to
make sure that it is operational. Squeeze and
release the trigger to ensure that the latch moves
freely and that the trigger closes.
6. Replace the meter onto the hose.

Connection Replacement

Connection Replacement Kit (18F173)
Disassembly
1. Follow Pressure Relief Procedure, page 7.
2. Loosen the swivel (33) from the hose and remove
the meter, then move to a work bench for repair.
3. Pull the impact guard (37) off of the meter (F
F
. 28
IG
4. Remove the four screws (9) (F
F
. 29
IG
16
. 28).
IG
37
. 29).
IG
9
5. Disassemble the bezel (1) from the meter housing
(10) (F
. 30).
IG
NOTE: Take care not to damage solenoid wire (14a).
14a
10
F
. 30
IG
6. Disconnect the solenoid wires (14a) from the
terminal block on the bezel (1) (F
1
14a
F
. 31
IG
1
2
. 31).
IG
Terminal
Block