Meter Replacement - Graco PM8 Repair Instructions

Hide thumbs Also See for PM8:
Table of Contents

Advertisement

Meter Replacement

Meter Replacement Kit s(18F176)
Disassembly
1. Follow Pressure Relief Procedure, page 7.
2. Loosen the swivel (33) from the hose and remove
the meter, then move to a work bench for repair.
3. Pull the impact guard (37) off of the meter (F
F
. 52
IG
4. Remove the four screws (9) (F
F
. 53
IG
3A8560C
. 52).
IG
37
. 53).
IG
9
5. Disassemble the bezel (1) from the meter housing
(10) (F
. 54).
IG
NOTE: Take care not to damage solenoid wire (14a).
14a
10
F
. 54
IG
6. Disconnect the solenoid wires (14a) from the
terminal block on the bezel (1) (F
1
14a
F
. 55
IG
Repair
1
2
. 55).
IG
Terminal
Block
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pm20

Table of Contents