Technical Specifications for h30 (QHC) Models

QUANTM h30 (QHC) Pumps
Maximum fluid working pressure
Maximum free-flow delivery
Maximum size pumpable solids
Environmental temperature range
Maximum operating altitude
Electrical ratings
h30 (QHC) models, FF1 motor
h30 (QHC) models, FF2 motor
h30 (QHC) models, FF3 motor
h30 (QHC) models, FF4 motor
h30 (QHC) models, FF5 motor
h30 (QHC) models, FF6 motor
Materials of construction
See Configuration Matrix, starting on page 7, for materials of construction for your equipment model.
Fluid inlet/outlet sizes
Models with wetted section materials coded:
Maximum suction lift*
Noise (dBa)
Maximum sound pressure
Sound pressure measured 1.6 feet (0.5 meter) from equipment.
Sound power measured per ISO-9614-2.
Weight
Models with wetted section materials coded:
Notes
*
May vary based on pump materials, suction condition, discharge head, pressure, and fluid type.
All trademarks or registered trademarks are the property of their respective owners.
50
US
100 psi
30 gpm
High Sanitation models 0.42 in.
All other models 1/8 in.
-4° to 104°F
9842 ft
Rated Voltage
FG
HS, PH, 3A
Wet 29.0 ft
Dry 7.9 ft
FG 88 lb
HS, PH, 3A 77 lb
Phase
200–240 V
3
200–240 V
1
200–240 V
3
200–240 V
1
100–120 V
1
100–120 V
1
1.5 in. sanitary flange or 40 mm DIN 11851
1.0 in sanitary flange or RD52 x 1/6 DIN
74 dBa at full power and flow
Metric
6.89 bar, 0.69 MPa
114 lpm
20.7 mm
3.2 mm
–20° to 40°C
3000 m
Hertz
Current
50/60 Hz
7.5 A
50/60 Hz
10 A
50/60 Hz
7.5 A
50/60 Hz
10 A
50/60 Hz
12 A
50/60 Hz
12 A
8.8 m
2.4 m
39.9 kg
34.9 kg