Option T, Percent Power Indicator; Option W, Water Cooled Heat Sinks; Accessory, Voltage Indicator; Technical Specifications - Ametek DPA1 Series Installation, Operation And Troubleshooting Instructions

Power controllers
Table of Contents

Advertisement

Description
1-22.

OPTION T, PERCENT POWER INDICATOR.

1-23.
The Percent Power Indicator is a 0 to 1 milliampere DC meter scales to indicate 0 to 100 percent
power. The accuracy of the meter is (+2) percent of the full scale deflection. The function of the indicator is to
measure ad display the percent of power supplied to the load. The Percent Power Indicator is used with the
Power Feedback and Current Limit Module (option Q, refer to paragraph 1-20).
1-24.

OPTION W, WATER COOLED HEAT SINKS.

1-25.
The Water Cooled Heat Sinks are recommended when units are to be enclosed in dust-tight
enclosures where a closed-system forced air cooling system is not desired or available. The water cooled
units designated DPAW-1, are physically different from the air cooled units and must be specified at time of
order.
1-26.

ACCESSORY, VOLTAGE INDICATOR.

1-27.
The Voltage Indicator is a 0 to 120 Volt AC Voltmeter. The indicator is connected across the 120 Volt
taps on a transformer in the DPA-1, and the face of the meter is changed at the factory to accommodate the
desired Voltage range. The function of the indicator is to measure and display the RMS output Voltage applied
to the load. The accuracy of the Voltage Indicator is (+5) percent of full scale deflection.
1-28.

TECHNICAL SPECIFICATIONS.

1-29.
The general technical specifications for the DPA-1 Series PHASE/AMPS are listed in the Table 1-2.
The model number, RMS current output, nominal load, and dimensions for DPA-1 PHASE/AMPS are listed in
Table 1-1.
1-30.

TECHNICAL ASSISTANCE.

1-31.
In the event that any question should arise concerning application or selection of available options and
accessories, prompt assistance may be obtained by calling AMETEK HDR Power Systems Customer Support
at 614-308-5500
Table 1-2 General Technical Specifications for DCPA-1/DPA-1 PHASE/AMPS
Control Signal
Input Level, Minimum
Input Level, Maximum
Input Impedance, Standard
Input Impedance, Optional
Input (Supply)
Voltage
Frequency
Output Voltage, DCPA-1 only
Output Linearity, DCPA-1 only
4
SPECIFICATIONS
0 to 1 mA DC
0 to 50 mA DC
1500 ohms, 0 to 12 mA span
500 ohms, 12 to 30 mA span
300 ohms, 30 to 50 mA span
Between – 20% and +10% of rated value
50 or 60 Hertz
0 – 87%
Within 2%
AMETEK HDR Power Systems
Phase/AMP Series DPA1/DCPA1
Document 9100030

Advertisement

Table of Contents
loading

Table of Contents