Stuart Turner 46647 Installation, Operation & Maintenance Instructions Manual

Stuart Turner 46647 Installation, Operation & Maintenance Instructions Manual

Advertisement

Available languages

Available languages

Quick Links

STUART
Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the owner as it contains important
guarantee, maintenance and safety information
Read this manual carefully before commencing installation.
This manual covers the following products suitable for 220/1/60 supply.
CH 4-30 FL
Pt. No. 46647
FOR POSITIVE HEAD APPLICATIONS ONLY
60 Hz
CH 4-40 FL
Pt. No. 46648
1
CE compliant product

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 46647 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stuart Turner 46647

  • Page 1 Read this manual carefully before commencing installation. This manual covers the following products suitable for 220/1/60 supply. CH 4-30 FL CH 4-40 FL Pt. No. 46647 Pt. No. 46648 FOR POSITIVE HEAD APPLICATIONS ONLY 60 Hz CE compliant product...
  • Page 2: Table Of Contents

    Arabic Installation Operation & Maintenance Instructions ....30 English (GB) Installation Operation & Maintenance Instructions ....2 PRODUCT DESCRIPTION Electric motor driven centrifugal pump complete with an automatic control system, consisting of flow switch, and electronic control.
  • Page 3 WARNINGS: This pump set must not be used for any other application without the written consent of Stuart Turner Limited. Do not connect this pump to the mains water supply. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...
  • Page 4 If the supply cord is to be changed or is damaged, it must be replaced with a special cord assembly available from Stuart Turner or one of their approved repairers. Please read installation details carefully as they are intended to ensure this product provides long, trouble free service.
  • Page 5: Checklist

    Outlet port removed from its packaging check for any damage prior to installation. If any damage is found contact Stuart Turner Ltd within 24 hours of receipt. Inlet port Fig. 1 Your product may vary slightly from the picture above.
  • Page 6 ASSEMBLY To protect the unit during tansit the pump is supplied with the flow switch removed. Follow the instructions below to complete assembly. Ensure all components are clean and free from debris. Screw complete flow switch body assembly into pump body, ensuring ‘O’-ring is fitted (Fig.
  • Page 7: Important Facts - Read Before Commencing Installation

    1 IMPORTANT FACTS: READ BEFORE COMMENCING PUMP INSTALLATION A Water storage capacity. 1.11 The water storage capacity must be sufficient to meet the flow rates required by the pumped equipment and any other water using fittings and appliances, which may be operated simultaneously. 1.12 Ensure the pump is primed as described in the priming section before starting, damage to the shaft seal will result otherwise.
  • Page 8: Location

    2 LOCATION - GENERAL 2.11 Access: For emergencies and maintenance the pump must be easily accessible. 2.12 Protection: The pump must be located in a dry position, frost free and protected from freezing, particularly when installed in a loft (not recommended). 2.13 Ventilation: Ensure an adequate air flow to cool the pump.
  • Page 9: Electrical Installation

    3 ELECTRICAL INSTALLATION / EARTHING 3.11 Regulations: The electrical installation must be carried out in accordance with the current local regulations by a qualified person. 3.12 Safety: In the interests of electrical safety a 30 mA residual current device (R.C.D. not supplied) should be installed in the supply circuit. This may be part of a consumer unit or a separate unit.
  • Page 10 3.21 If the supply cord is to be changed or damaged, it must be replaced by a special cord available from Stuart Turner or one of its approved repairers. - 10 -...
  • Page 11: Plumbing

    4 PLUMBING 4.11 Pipework: For optimum performance pipework use 28 mm dia., 22 mm can be used but will result in reduced pump performance. Pipework should only reduce to 15 mm when entering terminal fitting. 4.12 Isolating valves: Separate isolating valves (non restrictive) must be fitted to allow easy pump service.
  • Page 12 This product is maintenance free for its life, however it is a mechanical product and will eventually show signs of wear. Spare parts are available, for more information phone the Stuart Turner TechAssist team on +44 (0) 800 31 969 80.
  • Page 13: Technical Specification

    Weight (including fittings) 9.9 Kg 10.4 Kg Stuart Turner reserve the right to amend the specification in line with its policy of continuous development of its products. *Note: The maximum pressure that can be applied to the pump under any installation conditions.
  • Page 14: Trouble Shooting

    Check power supply. Check fuse (see fuse section). Check circuit breaker is set. Check wiring connections. Pump Jammed. If motor ‘Buzzes’ switch off power and contact Stuart Turner. Recommended static inlet/ Re-position pump (see pump location section). outlet heads exceeded. No flow.
  • Page 15: Guarantee

    Proof of purchase should accompany the returned unit to avoid delay in investigation and dealing with your claim. You should obtain appropriate insurance cover for any loss or damage which is not covered by Stuart Turner Ltd in this provision. Please record here for your records TYPE NO.
  • Page 16 .‫املعايري املطلوبة‬ .‫ مضمونة بأنها خالية من العيوب يف املواد أو الصناعة ملدة سنة واحدة من تاريخ ال رش اء‬Stuart Turner ‫إن جميع مضخات‬ ‫خالل فرتة الضامن، سنقوم بإصالح أي عيوب يف املضخة مجان ا ً نتيجة أخطاء يف املواد أو الصناعة، إىل جانب إصالح كل الوحدة أو‬...
  • Page 17 ‫6. استكشاف األعطال وإصالحها‬ ‫اإلج ر اء املوىص به‬ ‫السبب املحتمل‬ ‫األع ر اض‬ ‫قم بنزع خ ر اطيم اإلخ ر اج وتحقق من ضبط مفتاح التدفق بوضعية‬ .‫مفتاح تدفق مسدود‬ ‫الصاممات تعمل‬ .‫منخفضة. تحقق من أن العوامة تتحرك بحرية‬ .‫مبخارج...
  • Page 18 ‫6. استكشاف األعطال وإصالحها‬ ‫اإلج ر اء املوىص به‬ ‫السبب املحتمل‬ ‫األع ر اض‬ .‫تحقق من مصدر التزويد بالطاقة‬ .‫مصدر التزويد بالتيار الكهربايئ‬ ‫املضخة ال تبدأ‬ .)‫تحقق من الفيوز (أنظر قسم الفيوز‬ .‫التشغيل‬ .‫تحقق من أن قاطع الدارة مضبوط‬ .‫تحقق من توصيالت األسالك‬ ‫يف...
  • Page 19 )‫الوزن (مع التجهي ز ات‬ 10.4 .‫ بحق تعديل املواصفات مبا يتوافق مع سياستها املتمثلة يف التطوير املستمر ملنتجاتها‬Stuart Turner ‫تحتفظ رشكة‬ ‫مالحظة: يعترب أقىص ضغط عمل هو أقىص ضغط ميكن تطبيقه عىل غالف املضخة الداخيل تحت أي ظرف من‬...
  • Page 20 ‫ال يتطلب هذا املنتج صيانة طوال عمره االف رت ايض، لكنه منتج ميكانييك ومن ث م َّ ستظهر عليه يف النهاية عالمات البىل‬ ‫» برشكة‬TechAssist« ‫والتآكل. تتوفر قطع غيار هذا املنتج، ملزيد من املعلومات، ي ُ رجى االتصال بفريق الدعم الفني‬ ‫ عىل الرقم‬Stuart Turner 800 31 969 80 ‫ي...
  • Page 21 ‫4. أعامل السباكة‬ ‫مم، ميكن استخدام أنابيب‬ ‫أعامل األنابيب: للحصول عىل األداء األمثل ألعامل األنابيب استخدم أنابيب ذات قطر‬ 4.11 ‫مم عند إدخال‬ ‫مم لكن ذلك سيؤدي إىل االنخفاض يف أداء املضخة. أعامل األنابيب فقط يجب تقليلها اىل‬ ‫بقطر‬ .‫الرتكيب النهايئ‬ .‫صاممات...
  • Page 22 .‫أمبري مع جميع الط ر ا ز ات‬ ‫املصهر: ينبغي أن تستخدم مصاهر سعة‬ 3.19 :‫استبدال سلك التزويد بالطاقة‬ 3.20 ‫ينبغي توجيه األسالك الداخلية املوجودة يف الصندوق الطريف وشدها بإحكام لضامن االلت ز ام باملعيار‬ ‫. من الرضوري قبل حدوث أي تشويش يف هذه األسالك الداخلية، أن يتم‬ ‫الكهربايئ‬...
  • Page 23 ‫3. الرتكيب الكهربايئ / التأريض‬ .‫األنظمة: يجب أن تتم عملية الرتكيب الكهربايئ وفق األنظمة املعمول بها محلي ا ً من قبل شخص مؤهل‬ 3.11 ‫السالمة: من أجل تحقيق السالمة الكهربائية، ينبغي تركيب أداة تعمل بالتيار املتبقي سعة 03 ميل أمبري‬ 3.12 ‫(األداة...
  • Page 24 ‫2. املكان – عام‬ .‫الوصول: يجب أن يكون الوصول إىل املضحة سه ال ً يف حاالت الطوارئ وألغ ر اض الصيانة‬ 2.11 ‫الحامية: يجب وضع املضخة يف مكان جاف، خال من الصقيع ومحمي من التجمد، خاص ة ً عند تركيبها يف‬ 2.12 .)‫العلية...
  • Page 25 ‫حقائق مهمة: يرجى الق ر اءة قبل الرشوع برتكيب املضخة‬ .‫أ . سعة تخزين املاء‬ ‫يجب أن تكون سعة تخزين املاء كافية لتفي مبعدالت التدفق التي تتطلبها معدات املضخة، إىل جانب متطلبات أي‬ 1.11 .‫تجهي ز ات وأجهزة املاء املستخدمة األخرى، والتي ميكن تشغيلها يف آن واحد‬ ‫تأكد...
  • Page 26 ‫الرتكيب‬ .‫لحامية الوحدة أثناء نقلها قم بنزع مفتاح التدفق املزود مع الوحدة‬ .‫اتبع التعليامت أدناه المتام عملية الرتكيب‬ .‫تأكد من أن جميع املكونات نظيفة وخالية من األوساخ‬ • ‫قم بشد مجموعة هيكل مفتاح التدفق بال رب اغي بشكل كامل عىل هيكل املضخة، وتأكد من أن الحلقة «الدائرية» مثبتة‬ •...
  • Page 27 ‫هام: عند إ ز الة املضخة من عبوتها، قم بالتحقق من عدم‬ ‫منفذ إخ ر اج‬ ‫وجود تلف فيها قبل الرشوع يف تركيبها. يف حال تبني‬ Stuart Turner Ltd ‫وجود أي تلف، قم باالتصال برشكة‬ .‫ساعة من االستالم‬ ‫يف غضون‬...
  • Page 28 ‫يف حالة تلف سلك اإلمداد بالكهرباء أو تغيريه، فيجب استبداله مبجموعة األسالك‬ .‫ أو أحد مسؤويل اإلصالح املعتمدين لديها‬Stuart Turner ‫الخاصة املتوفرة من رشكة‬ ‫يرجى ق ر اءة تفاصيل الرتكيب بعناية كونها مخصصة لضامن أن يقوم هذا املنتج بتقديم خدمة لوقت أطول دون أي مشاكل. كام‬...
  • Page 29 :‫تحذير‬ ‫يجب عدم استخدام مجموعة املضخة هذه ألي تطبيق آخر دون الحصول عىل املوافقة‬ .Stuart Turner Limited ‫الخطية من رشكة‬ .‫ال تقم بتوصيل هذه املضخة بخطوط املاء الرئيسية‬ ‫ميكن لألطفال البالغني 8 أعوام فأكرث واألشخاص الذين يعانون من نقص يف القد ر ات‬...
  • Page 30: Arabic Installation Operation & Maintenance Instructions

    ..........‫تعليامت الرتكيب والتشغيل والصيانة باللغة العربية‬ .
  • Page 31 ‫ي ُ تبع‬ - 31 -...
  • Page 32 Signed ..........Stuart Turner are an approved company to BS EN ISO 9001:2015...

This manual is also suitable for:

Ch 4-40 flCh 4-30 fl46648

Table of Contents