3.18 Wiring diagram:
Fig. 4
3.19 Fuse: CH 4-30, 40, 50 use a 13 Amp fuse, CH 4-60 should use a 16 Amp fuse.
3.20 Supply cord replacement:
The internal wiring within the terminal box is routed and secured
to ensure compliance with the electrical standard IEC 60335-1. It
is essential that prior to any disturbance of this internal wiring, all
cable routing and securing details are carefully noted to ensure re-
assembly to the same factory pattern is always maintained.
3.21 If the supply cord is to be changed or damaged, it must be replaced by a
special cord available from Stuart Turner or one of its approved repairers.
3.22 Cable Gland Fitting Instructions:
To enable correct assembly of the cable gland the
'O'-ring (Fig. 5 item 1) must be placed over the cable
before the clamping insert (Fig. 5 item 2) can be
tightened.
Note: Cable diameter range:- 9.2 mm to 11.9 mm.
3.23 Supply Cord Extension:
The pumps are fitted with a supply cord to the
following specification:-
All models . . . . . . . . . . . . . .HO7RN-F3 G 1.5 mm² - 10 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should
be used. Any connections or junction boxes used should be specifically
suited for the application and installed in accordance with the manufacturers
instructions.
BROWN
BLUE
GREEN/YELLOW
- 9 -
RED
BLACK
1
2
Fig. 5
Cont ...