Appendix: Technical data

Technical data

Data sheet
Specification
HCH5 MKII
Max. recommended flow at 100Pa
Max. rated flow at 100Pa
Operating range Passivhaus at 100Pa
EN 13141-7 reference flow at 50Pa
Performance
Thermal efficiency in accordance with
EN13141-7
Leakage (external and internal) in accordance
with EN 13141-7
Filters in accordance with ISO16890
Filters in accordance with EN779:2012
Installation surrounding temperature
Outdoor temperature without preheater
installed
Outdoor temperature with preheater installed
Maximum absolute humidity of extract air
Cabinet:
Dimensions (with wall bracket)
Spigots/ducts connections
Weight
Thermal conductivity - polystyrene insulation
Heat transition figures- polystyrene insulation
Fire classification of the polystyrene insulation
Cabinet colour
Electrical
Voltage
Max. power consumption
(without/ with preheater)
Frequency
Protection class
* The use of preheating coil is recommended when outdoor temperature is below -3°C to
ensure balanced operation.

Appendix

Abbr .
V
100Pa
V
max.nom
V
PHI
V
ref
h
SUP
L
(A)
W
class
-
t
SURR
t
ODA
t
ODA
x
w x h x d
Ø
l
U
-
RAL
U
P
f
-
Unit
HCH5 MKII
m3/h
360
m3/h
300
m3/h
99-220
m3/h
210
%
88
dB(A)
<2% (Class A1)
ISO Coarse 75% (optional
-
on supply: ePM1>50% )
G4
-
(optional on supply: F7)
°C
-12 to +45
°C
-12* to +45
°C
-20 to +45
g/kg
10
mm
1180 x 633 x 580
mm
ø160 - female
kg
52
W/(mK)
0.031
W/(m
K)
U<1
2
DIN 4102-1 class B2
-
EN13501 class E
-
galvanized steel
V
230
W
170/1570
Hz
50
-
IP20
51