Valve Replacement - Regency Fireplace Products Grandview G800EC Owners & Installation Manual

Table of Contents

Advertisement

Valve Replacement

Removing Valve
1. Shut off the gas and electrical supply.
2. Remove the safety screen.
3. Remove the glass door.
4. Remove the logs and glass.
5. Remove the log grate assembly by removing
2 screws and sliding tray forward to remove.
Diagram 1: Remove the left and right
screws.
6. Remove bottom (brick or enamel) panel.
7. Remove 3 screws in locations shown below.Slide
the burner assembly to the right to release it
from the orifice, then lift it out.
Diagram 2: Slide burner assembly to the
right—then remove.
8. Remove 2 screws securing the light assembly
(Diagram 3) and rotate the assembly counter-
clockwise (Diagram 4).
Diagram 3
Diagram 4
9. Disconnect the inlet gas line.
10. Disconnect the EV1, EV2, and ground wires
from the valve - as shown below.
Diagram 5
EV1
10. Remove the 8 screws securing the valve tray
assembly in place (Diagram 6) and then lift out
entire assembly.
Diagram 6
Installing Valve
1. Place new valve tray into position
2. Reinstall the 8 hold down screws.
3. Hook up the EV1 and EV2 wires to the appropri-
ate connections on the valve.
4. Install the burner assembly
5. Hook up the gas line and check for gas leaks
with a soap and water solution or a gas leak
detector. (Do not use open flame for leak test-
ing.)
6. Fire up the unit temporarily
7. Check the manifold pressure.
8. Reinstall the inner panels, log grate, logs, and
media as needed.
9. Reinstall the door and screen door.
10. Fire up the unit again and check for proper
flame appearance and glow on logs.
EV2
Grandview
maintenance
G800EC Gas Fireplace |
89
®

Advertisement

Table of Contents
loading

Table of Contents