Lp Conversion Using Sit 885 Proflame Gas Valve - Regency Fireplace Products Grandview G800EC Owners & Installation Manual

Table of Contents

Advertisement

installation
G800EC

LP Conversion using SIT 885 PROFLAME Gas Valve

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
Each Kit contains one LP Conversion Kit
Conversion Kit #761-969 Contains:
Qty.
Part #
Description
1
904-947
Burner Orifice #53
1
904-529
5/32" Allen Key
1
918-590
Decal "Converted
to LPG"
1
908-528
Red "LP" label
1
910-037
LP Injector (Pilot
Orifice)
1
911-011
Stepper Motor
1
920-147c
Instruction Sheet
Installation of LP
Conversion Kit:
1. Shut off the gas and electrical supply.
2. Remove the safety screen*.
3. Remove the glass door*.
4.
Remove the logs, glass, and any other
media* if already installed.
5. Remove the two log supports* and log grate
assembly by removing 2 screws and sliding
the tray forward to remove.
*(See specific instructions in unit manual.)
Diagram 1: Remove the left and right screws.
6. Remove three screws then remove the burner
assembly.
Diagram 2: Slide burner assembly to the
right—then remove.
66
| Grandview
G800EC Gas Fireplace
®
920-147c
LP Conversion
G800EC using SIT 885 NOVA Gas Valve
IF IN DOUBT DO NOT DO THIS CONVERSION !!
7. Remove the pilot retainer clip below the
pilot cap.
Pilot retainer clip
8. Pull off the pilot cap to expose the pilot
orifice.
9. Unscrew the pilot orifice with the Allen key;
then replace with the LPG pilot orifice,
provided in the kit.
10. Re-install pilot cap and pilot retainer clip.
11. Remove burner orifice with a 3/8" wrench.
13. Loosen the two Phillips head screws as
14. Push the IFC Box back.
1
Use another wrench to hold on to the elbow
behind the orifice. Discard orifice.
12. Reinstall new burner orifice LPG stamped
#53 and tighten.
shown. They do not need to be removed.
*Firebox hidden for
clarity*
15. Rotate the front of the IFC box to the left.
11.18.21

Advertisement

Table of Contents
loading

Table of Contents