10. At the configurations menu, enter option 4 and press the ENTER
key to display the RTS/DTR menu associated with the V.35 Data
Port.
V.35 Port
Enter Selection (-(previous), q(uit), <1>): _
11.To toggle RTS from "Independent" to "Forced," enter option
number 1, then press the ENTER key and select 2 (for Forced)
and press the ENTER key. You will then see the updated V.35 Port
menu. Use "Forced" if you want CTS to stay high as long as the
carrier is high, regardless of the state of RTS; "Independent"
means CTS will follow the state of RTS. When the selections are
appropriate for your application, press the minus key "-" and then
the ENTER key to return to the Configurations menu.
Configurations
Enter Selection (-(previous), q(uit), <1>): _
12. Enter option 5 and press the ENTER key to set (implement) the
configuration settings you have just completed. This will display
"Configuration Setting Done" and you will be returned to the
Configurations menu.
13. Enter option 6 and press the ENTER key to set AND SAVE the
configuration settings you have just completed. This will also
display "Configuration Setting Done."
26
1. Force RTS
1. T1 Line Configuration
2. DS0 Speed/DS0 Allocation
3. Clocking
4. V.35 Port
5. Set configurations
6. Set and Save configurations
7. Reset to Factory Defaults
: Independent