Chapter 10 – V.24-V.25
Refer to ITU-T Recommendation V.25 specifications if you desire more details about the following commands.

Fixed DTE Rate +IPR

This command is used to specify the baud rate for the module DATA port. The factory default value is
Description:
115200. When autobaud is specified (AT+IPR=0), the module sets the DATA port operating baud rate to the
detected DTE baud rate. The AT&F command restores the baud rate value that was active when the last
AT&W command was used.
The use of baud rates below 9600 may affect the operability of some module software features; e.g.,
Note:
TCP App.
Command syntax: AT+IPR
Syntax:
Command
AT+IPR?
Note: Read syntax.
AT+IPR=?
Note: List of supported <rate> values,[(list of
fixed-only <rate> values)]
AT+IPR=38400
Note: Disable autobaud and set rate to 38400 bps
AT+IPR=0
(*) The first list of values are the baud rates that are detectable by the module autobaud feature. The second
list of values are the module DATA port supported baud rates

DTE-DCE Character Framing +ICF

This command is used to specify the UART start-stop (asynchronous) character framing for the module
Description:
DATA port. The factory default value is 3,3. The AT&F command restores the value that was active when
the last AT&W command was used.
Values:
<format>
Autodetect
0
8 Data 2 Stop
1
8 Data 1 Parity 1 Stop
2
8 Data 1 Stop
3
7 Data 2 Stop
4
7 Data 1 Parity 1 Stop
5
7 Data 1 Stop
6
<parity>
Odd
0
Even
1
Mark
2
None
3
The supported format values are software release specific. Use the +ICF=? command to display the valid
Note:
format values for the software release in use.
Command syntax: AT+ICF= <format>, <parity>
Syntax:
Command
AT+ICF=3,3
Note: Set values.
AT+ICF?
Note: Display current settings.
AT+ICF=?
Note: Display valid parameter ranges.
Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J)
Commands
Note: Enable autobaud
(Not supported)
(Not supported)
(Not supported)
(Supported)
(Not Supported)
(Not Supported)
(Not Supported)
(Supported)
(Supported)
(Supported)
(Supported)
Possible Responses
OK
Note: New values set
+ICF: 3,3
OK
Note: Current values
+ICF: (3-5),(0-3)
OK
Note: Possible values
Chapter 10 – V24-V25 Commands
Possible Responses
+IPR: 9600
OK
Note: Current rate is 9600 bps
+IPR: (0,1200,2400,4800,9600,19200), (45,50,75,
110,150,300,600,38400,57600,115200,230400)
OK
Note: Possible value (
OK
OK
.
)
*