Section 3: Meter maintenance
June 2011
14.

Figure 3-30 Transducer wiring and Acquisition cable reassembled

A.
B.
C.
D.
D.
A. Transducer wiring terminal blocks
B. Acquisition cable
C. Acquisition Module
D. O-ring
E. Base Enclosure
15.
16.
17.
18.
62
Plug the Acquisition cable terminal block into J3 on the Acquisition board and tighten
the terminal block screws with a 1/8 inch (3mm) flat blade screw driver.
Repeat these steps for other transducers you are replacing.
When you have completed wiring the transducer cables to the Acquisition Module,
check the Base Enclosure o-ring and reinstall if necessary.
Reattach the Transmitter Electronics Enclosure to the Base Enclosure with the four hex
head bolts and lock washers. Tighten bolts with a 7/16 inch (12mm)wrench.
Retighten or reattach the conduit to the Transmitter Electronics Enclosure using a
crescent wrench or channel lock pliers.
Maintenance and Troubleshooting Manual
Transducer housing Installation
3-9000-767 Rev A