Maintenance and Troubleshooting Manual
3-9000-767 Rev A
3.4.4
Acquisition Module replacement
1.
2.
3.
Figure 3-40 Conduit removal
A.
B.
A. Transmitter electronics enclosure
B. Conduit bolts
Acquisition Module replacement
Remove power to the meter.
Refer to
Figure 3-4
for the tools required to complete this procedure.
If the installation has rigid conduit, use a medium size crescent wrench and loosen the
hex nuts on the Transmitter Electronics Enclosure. This should allow enough slack to
remove the Transmitter Electronics Enclosure from the Base Enclosure. If the
installation uses flexible conduit, you may not need to disconnect it from the
Transmitter Electronics Enclosure.
Section 3: Meter maintenance
June 2011
75