Controller I/O - Universal Robots e Series User Manual

Control box
Hide thumbs Also See for e Series:
Table of Contents

Advertisement

Remote OFF button
This example illustrates connecting a remote OFF button.
CAUTION
Do not press and hold the ON input or the POWER button as it switches off the
Control Box without saving. You must use the OFF input for remote off control as
this signal allows the Control Box to save open files and shut down correctly.

5.1. Controller I/O

You can use the I/O inside the Control Box for a wide range of equipment including pneumatic
relays, PLCs and emergency stop buttons.
The illustration below shows the layout of electrical interface groups inside the Control Box.
Safety
24V
EI0
24V
EI1
24V
SI0
24V
SI1
You can use the horizontal Digital Inputs block (DI8-DI11), illustrated below, for quadrature
encoding Conveyor Tracking (see
input.
The meaning of the color schemes listed below must be observed and maintained.
Yellow with red text
e-Series Control Box
Remote
12V
GND
ON
OFF
Remote
12V
GND
ON
OFF
Remote
P ow er
Confi gurable Inputs
12V
P W R
24V
24V
GND
GND
CI0
CI4
ON
24V
24V
24V
OF F
0V
CI1
CI5
24V
24V
CI2
CI6
24V
24V
CI3
CI7
Common specifications for all digital
Confi gurable Outputs
Digital Inputs
0V
0V
24V
24V
CO0
CO4
DI0
DI4
0V
0V
24V
24V
CO1
CO5
DI1
DI5
0V
0V
24V
24V
CO2
CO6
DI2
DI6
0V
0V
24V
24V
CO3
CO7
DI3
DI7
Dedicated safety signals
Digital Outputs
Analog
0V
0V
AG
DO0
DO4
AI0
0V
0V
AG
DO1
DO5
AI1
0V
0V
AG
DO2
DO6
AO0
0V
0V
AG
DO3
DO7
AO1
I/O) for these types of
User Manual