Reference; Electrical Specifications - ACU-RITE 100S Reference Manual

Readouts for milling applications
Table of Contents

Advertisement

Electrical Specifications

Follow these specifications when installing your
Characteristic
Operating conditions
Storage conditions
Input requirements:
Voltage
Frequency
Current
Fuse
Encoder input
Size
Weight
Mounting
FCC compliance
CE compliance
ETL compliance
ETLc compliance
Specification
0° to 40°C (32° to 104°F)
25% to 85% relative humidity
(non-condensing)
-40° to 60°C (-40° to 140°F)
25% to 85% relative humidity
(non-condensing)
100 - 240 V~
50 - 60Hz
25 VA max
500mA, slo-blo
Position signals: channels A & B
TTL square wave signal in quadrature
(90° nominal phase relationship)
Maximum input rate: 70 kHz
9.875" x 4.679" x 4.75"
4 lbs., 2 oz.
Bottom; two 1/4"-20 threaded inserts
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) this device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired opera-
tion.
For Europe
For United States
For Canada

REFERENCE

system.
100S
33

Advertisement

Table of Contents
loading

Table of Contents