ACU-RITE 100S Reference Manual page 30

Readouts for milling applications
Table of Contents

Advertisement

Symptom
Screen is
blank
Decimal point
scrolls across
display
Dashes
appear on
screen
Reference Manual
100S
Probable Cause
No power to the
readout
LED failure
System has been idle
for approximately 90
minutes and is in
"display saver"
mode
Display overflow
TROUBLESHOOTING
Recommended
Corrective Action
Check that the power
switch on the back of the
console is "on."
Check that the readout's
power cord is properly
connected to the power
supply.
Check the fuse. (Located
above the power switch).
Check that the power
source meets the specifica-
tions required by your
system (pg. 33).
Contact your
100S
utor for repair/
replacement procedures.
Press any key or move the
table to return to the previ-
ous screen.
The value entered exceeds
the display's 8-character
capability. Enter a value
with less than 8
characters.
(cont'd next page)