ACU-RITE 100S Reference Manual page 32

Readouts for milling applications
Table of Contents

Advertisement

Symptom
Scale won't
count
Scale counts,
but not
correctly
Reference Manual
100S
Probable Cause
Loose cable
Wrong input
Scale not installed
properly
The scale's reading
head is not working
properly
Wrong scale
resolution
Wrong count
direction
Scale not installed
properly
TROUBLESHOOTING
Recommended
Corrective Action
Check that the scale cable
is securely connected to
the readout.
Check that the scale cable
is connected to the correct
input on the back of the
readout. Refer to the
readout installation
instructions.
Check the scale and read-
ing head for proper instal-
lation (refer to scale instal-
lation instructions).
Unplug the scale from the
readout and plug it into an
input for another axis.
If the scale still does not
count, the reading head
may need to be replaced. If
the scale counts on the
other axis then the display
may need to be replaced.
See LED Failure.
Check that the correct scale
resolution for the correct
axis was selected (pg. 9).
Change the count direction
(pg. 10).
Check the scale and reading
head for proper installation
(refer to scale installation
instructions included with
your system). Clean the
scale, if necessary.
29