Appx. 4 Alert Messages - Furuno FE-800 Operator's Manual

Navigational echo sounder
Hide thumbs Also See for FE-800:
Table of Contents

Advertisement

APPX. 4 ALERT MESSAGES

The alert modes Alert I/F1, Alert I/F2 and Legacy settings are set during the initial installation.
Consult a FURUNO technician to change these settings.
Alert I/F2
Alert
Alert Title
Description
Text
SHALLOW
TCVR1 FORE
DEPTH
depth below
keel alarm.
TCVR1 AFT
depth below
keel alarm.
TCVR2 FORE
depth below
keel alarm.
TCVR2 AFT
depth below
keel alarm.
LOST
TCVR1 TX volt-
MEAS
age ERR
stopped
MEAS.
TCVR2 TX volt-
age ERR
stopped
MEAS.
TCVR1 RX
voltage ERR
stopped
MEAS.
TCVR2 RX
voltage ERR
stopped
MEAS.
TCVR1 tem-
perature ERR
stopped
MEAS.
TCVR2 tem-
perature ERR
stopped MEAS
Priority/
Alert ID,
Category
Instance
Alarm/A
3031, 1
Alarm/A
3031, 2
Alarm/A
3031, 3
Alarm/A
3031, 4
Warning/B
3008, 1
Warning/B
3008, 4
Warning/B
3008, 2
Warning/B
3008, 5
Warning/B
3008, 3
Warning/B
3008, 6
AP-7
Meaning
Depth at fore transducer is
shallower than that set for
the alarm.
Depth at aft transducer is
shallower than that set for
the alarm.
Depth at fore2 transducer
is shallower than that set
for the alarm.
Depth at aft2 transducer is
shallower than that set for
the alarm.
Transceiver 1 PWR board
or TRX board may be dam-
aged. Voltage is not within
safe guidelines
Transceiver 2 PWR board
or TRX board may be dam-
aged. Voltage is not within
safe guidelines.
Transceiver 1 PWR board
or TRX board may be dam-
aged. Voltage is not within
safe guidelines.
Transceiver 2 PWR board
or TRX board may be dam-
aged. Voltage is not within
safe guidelines.
Transceiver 1 Tempera-
ture is above safe guide-
lines.
Transceiver 2 Tempera-
ture is above safe guide-
lines.
Measures
Check the
depth visually.
Consult a FU-
RUNO techni-
cian.

Advertisement

Table of Contents
loading

Table of Contents