Connecting Electrical Loads; Do Not Overload Generator; Gfci Module And Master Circuit Breaker - Champion PRO 100430 Operator's Manual

6500w electric start generator
Table of Contents

Advertisement

100430 - 6500W ELECTRIC START GENERATOR

Connecting Electrical Loads

Let the engine stabilize and warm up for a few minutes after
starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC
single phase, 60 Hz electrical loads.
– DO NOT connect 3-phase loads to the generator.
– DO NOT overload the generator.
– Use only a high quality, insulated, compatible (3-wire or
4-wire) grounded cord set rated equal to or greater (volts and
amps) than the receptacle plugging into.
Always remember to plug your appliances directly into the
generator and do not plug the generator power cord into any
electrical outlet or connect to the circuit breaker panel in your
home. Connecting a generator to your home's electric utility
company's power lines, or to another power source, called
'backfeeding' is a dangerous practice that is illegal in many
states and municipalities.
This action if done incorrectly could damage your generator,
appliances and could cause serious injury or death to you
or a utility worker when attempting to restore power during
an outage occurrence in the neighborhood who may then
unexpectedly encounter high voltage on the utility line and
suffer a fatal shock.
Whether injuries occur or not, if installed incorrectly and not to
applicable laws and codes, you may be subject to fines or the
utility company may disconnect your home power should this
practice be found in your home.
If the generator will be connected to a building electrical
system, those connections must isolate the generator power
from the utility power. You are responsible for ensuring your
generator's electricity does not backfeed into the electric
utility power lines. These connections must comply with all
applicable laws and codes – Consult your local utility company
or a qualified electrician to properly install this connection.

Do Not Overload Generator

Capacity
Follow these simple steps to calculate the running and starting
watts necessary for your purposes:
1. Select the electrical devices you plan on running at the same
time.
2. Total the running watts of these items. This is the amount of
power you need to keep your items running.
WARNING
3. Identify the highest starting wattage of all devices identified
in step 1. Add this number to the number calculated in step 2.
Starting wattage is the surge of power needed to start some
electric driven equipment. Following the steps listed under
"Power Management" will guarantee that only one device will
be starting at a time.
Power Management
Use the following formula to convert voltage and amperage to
watts:
Volts × Amps = Watts
To prolong the life of your generator and attached devices, follow
these steps to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to get up to
temperature.
3. Make sure all circuit breakers are set to the run position.
4. Plug in and turn on the first item. It is best to attach the item
with the largest load first.
5. Allow the engine to stabilize.
6. Plug in and turn on the next item.
7. Allow the engine to stabilize.
8. Repeat steps 5-6 for each additional item.
Never exceed the specified capacity when adding loads to the
generator.

GFCI Module and Master Circuit Breaker

This generator is equipped with a ground fault circuit interrupter
(GFCI) module and master circuit breaker. The GFCI constantly
monitors the current balance and in the event of a ground fault,
sends a signal to the master circuit breaker to trip and stop the
flow of electricity to all receptacles. When in normal operating
state, the green power LED will be lit on the GFCI module and
the circuit breaker will be in the "ON" position. If a ground fault
occurs, the red fault LED will blink on the module and the circuit
breaker will be tripped in the "OFF" position. The top of the circuit
breaker rocker switch will show red. To reset, first press the
"RESET" button on the GFCI module, then press the top of the
front face of the circuit breaker to the "ON" position. If a ground
fault occurs again, turn off the generator, inspect all cords plugged
into the generator for shorts, and inspect the grounding of the
generator. See the Grounding section of this manual for proper
grounding of the generator.