93001i-UK - 3000W PORTAbLE INvERTER GENERATOR
5. When starting the engine, pull the recoil cord slowly until
resistance is felt, release cord back and with one strong rapid
pull to start, this avoids any kickback or damage to the recoil
assembly. If the engine doesnt start repeat this process
A
Rigorously or aggressively pulling the recoil cord will result in
damage to the recoil assembly and void any warranty.
6. As the engine warms up, move the EZ Start dial to the "RUN"
position.
For petrol restarts with hot engine and(or) in hot ambient
temperature >86°F (30°C): Rotate the EZ Start dial to
the "CHOKE" position for only one pull of the recoil cord. If
generator does not start after first pull, rotate the dial to the
"RUN" position for the next three pulls. Too much choke leads
to spark plug fouling and engine flooding. This will cause the
engine not to start.
For petrol starting in standard ambient temperature
>59°F (15°C): Keep EZ Start dial in "CHOKE" position for three
pulls of the recoil cord. If generator does not start after three
pulls, rotate the EZ Start dial to the "RUN" position for the next
three pulls. Too much choke leads to spark plug fouling and
engine flooding. This will cause the engine not to start.
WARNING
NOTICE
NOTICE
For petrol starting in cold ambient temperature < 59°F
(15°C): Keep the EZ Start dial in the "CHOKE" position until
engine starts. As soon as the engine starts and runs smoothly
turn the EZ Start dial to the "RUN" position. In extreme cold
temperatures, this may take several seconds.
If the engine starts but does not continue to run make certain
that the generator is on a flat, level surface. The engine is
equipped with a low oil sensor that will prevent the engine
from running when the oil level falls below a critical threshold.

Connecting Electrical Loads

Let the engine stabilize and warm up for a few minutes after
starting.
Plug in and turn on the desired 240 Volt AC single phase, 50 Hz
electrical loads.
– DO NOT connect 3-phase loads to the generator.
– DO NOT overload the generator.
Always remember to plug your appliances directly into the
generator and do not plug the generator power cord into any
electrical outlet or connect to the circuit breaker panel in your
home. Connecting a generator to your home's electric utility
company's power lines, or to another power source, called
'backfeeding' is a dangerous practice that is illegal in many
states and municipalities.
This action if done incorrectly could damage your generator,
appliances and could cause serious injury or death to you
or a utility worker when attempting to restore power during
an outage occurrence in the neighborhood who may then
unexpectedly encounter high voltage on the utility line and
suffer a fatal shock.
Whether injuries occur or not, if installed incorrectly and not to
applicable laws and codes, you may be subject to fines or the
utility company may disconnect your home power should this
practice be found in your home.
If the generator will be connected to a building electrical
system, these connections must isolate the generator power
from the utility power. You are responsible for ensuring your
generator's electricity does not backfeed into the electric
utility power lines. These connections must comply with all
applicable laws and codes – Consult your local utility company
or a qualified electrician to properly install this connection.