Propane (Lpg); Connecting Electrical Loads - Champion 100397 Operator's Manual

3500w dual fuel generator
Table of Contents

Advertisement

100397
ENGLISH

Propane (lPG)

1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical
devices plugged in or turned on.
3. Fully open the LPG cylinder fuel knob.
4. Turn the LPG fuel valve to the "ON" position.
5. Move the choke lever to the "75% Choke" detent turn
position. (A)
a. For restarting a warm engine, move the choke
lever to the "75% CHOKE" detent position.
A
6. Push the ignition switch to the "ON" position.
7. Push the battery switch to the "ON" position.
8. ELECTRIC START: Press and hold the ignition switch
to the "START" position. Release as the engine begins
to start. If the engine fails to start within five seconds,
release the switch and wait at least ten seconds before
attempting to start the engine again.
9. RECOIL START: Pull the starter cord slowly until
resistance is felt and then pull rapidly.
10. Do not over-choke. As soon as engine starts, gradually
move the choke lever to the "RUN" position over a 2-5
second duration.
NOTE
If the engine starts but does not run make certain
that the generator is on a flat, level surface. The
engine is equipped with a low oil sensor that will
prevent the engine from running when the oil level
falls below a critical threshold.
Propane (lPG) Cont'd.
CAUTION
If the ignition switch is held down in the "Start"
position longer than 5 seconds it could damage the
starter.
NOTE
When the battery switch is in the "ON" position,
the switch will light up if the battery is sending
out a charge. If the switch does not light up while
in the "ON" position, check that the battery
connection is still good.
NOTE
The supplied 12V 9AH battery does re-charge while
the engine is running, but it is also recommended
that the battery be fully charged at least once per
month.

Connecting Electrical loads

1. Let the engine stabilize and warm up for a few
minutes after starting
2. Plug in and turn on the desired 120 Volt AC single
phase, 60 Hz electrical loads.
– DO NOT connect 3-phase loads to the generator.
– DO NOT connect 50 Hz loads to the generator.
– DO NOT overload the generator.
WARNING
Connecting a generator to your electric utility
company's power lines or to another power source
may be against the law. In addition this action,
if done incorrectly, could damage your generator
and appliances and could cause serious injury or
even death to you or a utility worker who may be
working on nearby power lines. If you plan to run a
portable electric generator during an outage, please
notify your electric utility company immediately
and remember to plug your appliances directly
into the generator. Do not plug the generator into
any electric outlet in your home. Doing so could
create a connection to the utility company power
lines. You are responsible for ensuring that your
generator's electricity does not feed back into the
electric utility power lines.
If the generator will be connected to a building
electrical system, consult your local utility company
or a qualified electrician. Connections must isolate
generator power from utility power and must comply
with all applicable laws and codes.