Outputs; Tab. 9 Outputs Ao_1; Tab. 10 Outputs Vref_10V; Tab. 11 Sensor Output Vext_Sen - Jetter JXM-IO-E32 User Manual

Expansion module
Hide thumbs Also See for JXM-IO-E32:
Table of Contents

Advertisement

Jetter AG

4.6 Outputs

Analog outputs
Outputs VREF_10V
Sensor output
VEXT_SEN
User Manual – JXM-IO-E32
Parameter
Analog output
Abbreviation
Quantity
Mode
Accuracy (current)
Accuracy (voltage)
Resolution
Tab. 9: Outputs AO_1 ... AO_3
Parameter
Abbreviation
Quantity
Operating voltage
Accuracy
Operating current
Accuracy
Diagnostic function
Tab. 10: Outputs VREF_10V
Parameter
VEXT_SEN is the 24 V output for supplying power to external sensors and
is supplied from VBAT_ECU.
Abbreviation
Quantity
Operating voltage
Accuracy
Operating current
Accuracy
Diagnostic function
Tab. 11: Sensor output VEXT_SEN
Description
AO
3
0 mA ... 20 mA
or
0 V ... 10 V: 20 mA max.
±2.5 % of the value range
100 mV
12 bits configured in mV
Description
VREF_10V
2
10 V
1 %
Min. 100 mA
1 %
The voltage generated at the 10 V power supply unit
can be read out via SDO. Each channel can be
checked for short circuit.
Description
VEXT_SEN
8
VBAT
1 %
100 mA
1 %
Each channel can be checked for short circuit.
Technical specifications | 4
It is possible to switch
between the configura-
tion as current output or
voltage output.
14 / 55