10.3 Ordinary maintenance

10.3.1 Maintenance of flue manifold
Remove the ash drawer and, using a special ash
vacuum, remove any residues in the compart-
ment that contains it. Use a flexible brush to clean
the exchanger pipes in the combustion chamber
(Fig. 58).
Remove any residues that fall in the flue manifold
using an ash vacuum.
96
10.3.2 Door safety
In order to guarantee the correct and safe opera-
tion of the fire box door, it is necessary to lubricate
the springs of the closing mechanism, which may
be located at the hinges (A) or at the door closing
latch (B).
Indicative image
10.3.3 Maintenance of the smoke system
If there are horizontal sections, it is necessary to
check and remove any deposits of ash and soot
before they obstruct the passage of fumes.
The incrustations inside the flue affect the
optimum forced draught. When they reach a
thickness of 5-6 mm, with high temperatures
and sparks, they can ignite with easily imaginable
consequences both for the flue and for the house.
In the event of failure to clean or inadequate
cleaning the appliance may have operating prob-
lems including:
• bad combustion;
• blackening of the glass;
• blockage of the burn pot with accumulation of
ash and pellets;
Fig. 58
• deposit of ash and excessive deposits on the ex-
changer with consequent poor performance.
A
B
004778982 - 09/08/2022
Fig. 59