Levelling Of The Appliance; Room Air Circulation - Palazzetti ECOFIRE VIVIENNE User Manual

Table of Contents

Advertisement

Available languages

Available languages

7.5

Levelling of the appliance

The appliance must be levelled with the help of a spirit
level, by regulating the adjustable feet (Fig. 47).
A = Spirit level.
A
7.6

Room air circulation

The stove is designed for ductable rear hot air
connection.
In order to function correctly, the PRO 2
and PRO 3 models must be ducted.
In the event that ducting is not fore-
seen, it is necessary to:
• inhibit the operation of the fans by
electrically disconnecting them and
appropriately insulating their termi-
nals to avoid possible contact with
metal and/or hot parts
• close the unused outlets with the spe-
cial cap supplied as an accessory.
To connect the stove to the ducted heating system,
connect a pipe (B) to the rear fan (A) on one side and
to the air distribution outlet (C) on the other side, se-
curing it with a hose clamp.
When the stove is used to heat two or more adjacent
rooms, it is essential to encourage recirculation of the
ambient air to uniform the temperature in the various
rooms.
For air ducting, preferably use smooth,
internally insulated pipes.
88
7.6.1
PRO 2
TA
Fig. 47
Room thermostat for rear fan control (PRO 2)
It is possible to connect a room thermostat to the
terminal board of the stove so that the rear fan can be
switched on and off according to the temperature set
on the thermostat.
To use this function, rear fan ventilation must be set
to ON.
The thermostat that controls the rear fan must be
connected to terminals 5 and 6 of the terminal board
in place of the bridge.
C
B
A
Fig. 48
004778982 - 09/08/2022