ONLY FOR VIVIENNE and CLELIA TC
On the first vertical tee, at the flue gas outlet of the
appliance, a pipe must be connected at the bottom to
drain any condensate that may form in the chimney
(Fig. 27).
ONLY FOR VIVIENNE US
As an additional safety measure, a threaded coupling
with "R" closing cap is provided in order to connect a
condensate drain pipe (Fig. 28).
004778982 - 09/08/2022
6.6
The chimney for the evacuation of flue gases must
be made by qualified personnel in compliance with
standards UNI 10683- EN 1856-1-2- EN 1857-EN 1443-
EN 13384-1-3- EN 12391-1 both in terms of the dimen-
sions and the materials used in its construction.
The flue gases can be evacuated through a tradi-
tional chimney (Fig. 29 - Fig. 30-) provided the good
condition and proper maintenance of the chimney
has been verified. In the case of an old chimney, it is
advisable to renew it using ducting.
The flue gas exhaust must be on the roof.
VIVIENNE US
Fig. 27
R
Fig. 28
1) Wind-proof cowl
2) Seal
3) Inspect
ITALIANO
ENGLISH

Roof exhaust with traditional fireplace

2
FRANÇAIS
1
3
Fig. 29
79