User Manual V1.1-2022-11-15
For MS 16A inverter
Technical Data
Input
Max. Input Power (W)
Max. Input Voltage (V)
MPPT Operating Voltage Range
(V)
MPPT Voltage Range at Nominal
Power (V)
Start-up Voltage (V)
Nominal Input Voltage (V)
Max. Input Current per MPPT (A)
Max. Short Circuit Current per
MPPT (A)
Max. Backfeed Current to The
Array (A)
Number of MPP Trackers
Number of Strings per MPPT
Output
Nominal Output Power (W)
Nominal Output Apparent Power
(VA)
Max. AC Active Power (W)
Max. AC Apparent Power (VA)
Nominal Power at 40℃ (W) (Only
for Brazil)
Max Power at 40℃ (Including AC
Overload) (W) (Only for Brazil)
Nominal Output Voltage (V)
Output Voltage Range (V)
Nominal AC Grid Frequency (Hz)
AC Grid Frequency Range (Hz)
Max. Output Current (A)
Max. Output Fault Current (Peak
and Duration) (A)(at 5ms)
Inrush Current (Peak and
Duration) (A)(at 50μ s)
Nominal Output Current (A)
Power Factor
GW5000-MS
10000
600
80~550
150~500
80
360
16
20
0
3
1
5000
5000
5500
*1
5500
*2
5000
5500
220/230/240
180~265
50/60
45~55 / 55~65
25.0
74
150
21.7
~1 (Adjustable from 0.8 leading to 0.8 lagging)
10 Technical Parameters
GW6000-MS
12000
600
80~550
200~500
80
360
16
20
0
3
1
6000
6000
6600
6600
6000
6600
220/230/240
180~265
50/60
45~55 / 55~65
30.0
74
150
26.1
39
GW7000-MS
13500
600
80~550
240~500
80
360
16
20
0
3
1
7000
7000
7700
7700
7000
7700
220/230/240
180~265
50/60
45~55 / 55~65
35.0
74
150
30.4