ICP DAS USA ZT-2000 DIO Series Quick Start Manual

ICP DAS USA ZT-2000 DIO Series Quick Start Manual

Advertisement

Quick Links

ZT‐2000 DIO SERIES 
1
What's in the Shipping Package?
The shipping package contains the following items:
ZT‐2000 DIO Device 
If any of these items are missing or damaged, please contact your local distributor
for more information. Save the shipping materials and cartons in case you need to
ship the module in the future.
2
Preparing the Device 
Refer the chapter 3. to configure the DIP switch of ZT-2000 I/O device.
1.
Install the ZT Configuration Utility to configure the ZT-2000 coordinator.
2.
CD: \Napdos\ZigBee\ZT_Series\Utility
http://ftp.icpdas.com/pub/cd/usbcd/napdos/zigbee/zt_series/utility
Power Supply: +10 ~ +30 V
3.
ICP DAS, ZT‐2000 DIO SERIES Quick Start, Version 1.2.1
Copyright 
ANT‐124‐05 
DC
+Vs
GND
©
 2013 by ICP DAS Co., Ltd. All Rights Reserved. 
Quick Start
Quick Start 
+Vs
GND
   Page 1 
 
 
 
 

Advertisement

loading

Summary of Contents for ICP DAS USA ZT-2000 DIO Series

  • Page 1 ZT‐2000 DIO SERIES  Quick Start   What’s in the Shipping Package? The shipping package contains the following items: ZT‐2000 DIO Device  ANT‐124‐05  Quick Start    If any of these items are missing or damaged, please contact your local distributor for more information. Save the shipping materials and cartons in case you need to  ...
  • Page 2  Setting up the ZT‐2000 DIO Device 3.1 Introduction to the Configuration Parameters  A. “Pan ID” parameter is the group identity for a ZigBee network, and must the same for all devices in the same ZigBee network. “Address/Node ID” parameter is the individed identity of a specific the ZigBee module, and must be unique for each device connected the same ZigBee network.
  • Page 3  Rotation Switch and DIP Switch  The configuration of ZT-2000 series can be adjusted by using the external rotary switch and the DIP switches. The ZT-2000 device should only be rebooted once the configuration is complete. DIP Switch to the ZT‐2042/ZT‐2043/ZT‐2053/ZT‐2055  Protocol Pan ID 10 11 12 Address LSB Address MSB Checksum RF Channel...
  • Page 4: Rotation Switch

     Rotation Switch  Note …… Address …… MSB = 0 Node ID 0x0001 0x0002 0x003 0x000F …… …… Address …… MSB = 1 Node ID 0x0010 0x0011 0x0012 0x013 0x001F …… ※ Once the address of hardware switch is set to 0x00, it mens the address is using software configurations.
  • Page 5  Start‐up ZT‐2000 I/O Device  As the ZigBee network is controlled by the ZigBee coordinator, the ZT-2550/ZT-2570 (ZigBee coordinator) must be configured first. Please refert to documents shown below for full details of how to configure these devices. Once configuration of the ZigBee coordinator has been completed. Set the ”Pan ID”...
  • Page 6  Examples   Configurations of ZT‐2550/ZT‐2570      ZT-2000 I/O Device  Configurations of  10 11 12   Number Item Status Explain Address MSB Address/Node ID is 01(Rotation Switch=1) Protocol Use Modbus RTU Protocol Checksum Disabled ZigBee Pan ID Pan ID=0x0000 0x08 ZigBee 0x04 ZigBee RF Channel = 0x0E RF Channel 0x02...
  • Page 7: Communication Test

     Communication Test  Once the ZT-2000 I/O device has joined the ZigBee network, the signal quality can be comfirmed by monitoring the status of the ZigBee Net LED indicators. If the LED indicator shows a steady light, communication with the ZT-2000 I/O device has been successfully established for data acquisition and control.
  • Page 8: Troubleshooting

     Troubleshooting  (1) Technical Support. If you have any difficulties using your ZT-2000 series I/O device, please send a description of the problem to service@icpdas.com Include the following items in your email: A description or diagram of the current DIP switch positions. ...