4-3 ADJUSTMENTS IN THE ADJUSTMENT MODE
M ENTERING THE ADJUSTMENT MODE
1) Connect the short plug (Page 4-1) to [REMOTE], and while holding down [MIC/RF PWR] and [SPEED/PITCH], turn ON the
power to enter the Adjustment mode.
2) The main adjustment menu appears.
M MAIN ADJUSTMENT MENU SCREEN
Select the ID adjustment
(Page 4-3 and 4-4)
Select the transmit adjustment (Page 4-5)
M QUITING THE ADJUSTMENT MODE
1) Remove the short plug from [REMOTE], and then turn OFF the power.
2) Turn ON the power again.
4-4 ID ADJUSTMENTS
Reterns to the adjustment screen.
1) Set or modify the adjustment value as specifi ed by rotating [MAIN DIAL].
2) Push [SET] to store the value.
ADJUSTMENT ITEM
ID REFERENCE
1 • Display: "13.8 SET"
VOLTAGE LOAD
ID REFERENCE SET
2 • Display: "ID HF+1.0A"
3 • Display: "ID V/UHF+1.0A"
4 • Display: "DID +0.7A"
TRANSCEIVER'S CONDITION
• Power supply voltage: 13.8 V
Adjustment value
Select the receive adjustment (Page 4-9)
Select the reference frequency (Page 4-8)
SET
Stores the value and move to the next item.
OPERATION
4-3
ADJUST
VALUE
POINT
Push [SET].
(A beep sounds,
and then another
beeps sound 0.5 sec.
later. Then the next
adjustment item is
selected.)
Push [SET].
(The next adjustment
item is selected.)

Advertisement