Mitsubishi Electric CITY MULTI PUMY-P112VKM6 Service Manual page 7

Advertisement

3
OVERVIEW OF UNITS
3-1. System construction
Outdoor unit
Applicable indoor unit
Model type
Cassette
2 by 2
ceiling
2-way flow PLFY-P·VLMD-E
4-way flow PLFY-P·VEM-E
1-way flow PMFY-P·VBM-E
Ceiling concealed
Wall mounted
Ceiling suspended
Floor
Exposed
standing
Concealed
Ceiling
Fresh air
concealed
Lossnay
Air to Water unit
*2
Remote controller
*1. When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit
capacity is 110%.
*2. When connecting PWFY series (Note that the connection is not allowed inside EU countries and the UK.)
Only 1 PWFY-P100VM-E-AU can be connected. PWFY-P200VM-E-AU and PWFY-P100VM-E-BU cannot be con-
nected.
The PWFY unit cannot be the only unit connected to an outdoor unit. Select an indoor unit so that the total rated
capacity of the indoor units, excluding the PWFY unit, is 50 to 100% of the outdoor unit capacity.
*3. PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "3-4-3. Operating temperature range".
*4. Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
*5. When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual
for the CONNECTION KIT.
*6. The CONNECTION KIT cannot be connected to the indoor unit whose model name is 60 or larger and LN 18.
OCH790 _7
Horsepower
Model name
Capacity class
Number of units
Total system capacity range
Model name
CMY-Y62-G-E
Number of branches
Connectable indoor unit lineup
10
Model name
PLFY-P·VFM-E
PLFY-M·VEM6-E
PLFY-M·VEM-E
PEFY-P·VMA(L)-E/E2
PEFY-P·VMA(L)-E3/E4
PEFY-P·VMHS-E
PEFY-P·VMR-E-L/R
PEFY-M·VMA-A1
PKFY-P·VLM-E
PKFY-P·VKM-E
PCFY-P·VKM-E
PFFY-P·VLEM-E
PFFY-P·VKM-E
PFFY-P·VLRM(M)-E
PFFY-P·VCM-E
PEFY-P·VMHS-E-F
*3
GUF·RD(H)4
*4
PWFY-P·VM-E1/E2-AU
Name
M-NET remote controller
Model name
PAR-F27MEA-E, PAR-U02MEDA
Functions
• A handy remote controller for use in conjunction
with the Melans centralized management system.
• Address setting is required.
4.5 HP
P112
1 to 9
50 to 130% of outdoor unit capacity
CMY-Y64-G-E
2
4
15
20
25
32
40
50
63
5 HP
P125
10 to 140
1 to 10
*1 *2
CMY-Y68-G-E
8
CONNECTION KIT
71
80
100 125 140
PAC-LV11M-J
M series indoor unit
MSZ-SF·VA/VE series
MSZ-EF·VE/VG(K) series
MSZ-FH·VE series
MFZ-KJ·VE series
MFZ-KT·VG series
MFXZ-KW·VG series
MSZ-LN·VG(2) series
MSZ-AP·VG(K) series
MSZ-AP·VF series
Wireless remote
controller
MA remote controller
PAR-4xMAA, PAR-3xMAA ("x" represents 0 or later)
• Address setting is not required.
6 HP
P140
1 to 12
*5, *6