Download Print this page

Mitsubishi Electric CITY MULTI PUMY-P112VKM6 Service Manual page 112

Advertisement

Photo 13
Valve bed
fixing screw
Compressor
(MC)
Separator
14. Removing the accumulator
1. Remove the service panel. (See Photo 1)
2. Remove the top panel. (See Photo 1)
3. Remove 2 cover panel (front) fixing screws (5 × 12) and remove the cover panel (front). (See Photo 4)
4. Remove 4 cover panel (rear) fixing screws (5 × 12) and remove the cover panel (rear).
5. Remove the electrical parts box. (See Photo 5)
6. Remove 3 side panel (R) fixing screws (5 × 12) in the rear of the unit and then remove the side panel (R).
7. Remove 3 side panel (R) fixing screws (5 × 12) in the rear of the unit and then remove the side panel (R).
8. Recover refrigerant.
9. Remove 4 welded pipes of accumulator inlets and outlets.
10. Remove 2 accumulator leg fixing screws (4 × 10).
Note:
• Recover refrigerant without spreading it in the air.
Photo 14
OCH790 _112
Figure 1
Valve
bed
fixing
screws
Accumulator
Compressor
fixing nuts
Separator
fixing screw
Photo 15
Inlet
Outlet
Accumulator
Accumulator leg fixing screws
Separator
fixing
screws
Accumulator
Accumulator
leg

Advertisement

loading